Specifications
5-20
Cisco ONS 15216 EDFA Operation Guide
78-12818-01
Chapter 5 Command Line Reference
Setup Commands
Example 5-17 SETOUT Command:
0-0>SETOUT aa.a
LD 1: Const Pump Power 75(mW)
LD 2: Const Outp Power bb(mW)
0-0>SETOUT 0
0-0>LD
LD 1: Idle
LD 2: Idle
0-0>
Use Table 5-11 to interpret SETOUT command details.
SETP
Explanation:
The SETP command sets Laser diode “1” or “2” to constant pump laser power mode (Example 5-18).
The GAIN alarm is automatically disabled when the SETP command is successfully issued.
A value of zero for the pump power setpoint places the pump in IDLE mode. In this case, no control
mode line is displayed after the SETP command.
Example 5-18 SETP Command:
0-0>SETP n xxx
LD n: Const Pump Power xxx(mW)
0-0>SETP n 0
0-0>
Table 5-12 can be used to interpret the SETP command details.
Table 5-11 EDFA Power Parameters
Parameter Format Description
aa.a 0..65.0 Set EDFA output power setpoint
with 0.1mW
bb 0..65 Current output power setpoint is
rounded to nearest whole number
Command: SETP
Syntax: SETP 1|2 <value, decimal (0-100mW)>
Password: Yes
Configuration: Yes
Brief Description: Sets specified laser to constant pump power mode