Specifications

5-19
Cisco ONS 15216 EDFA Operation Guide
78-12818-01
Chapter 5 Command Line Reference
Setup Commands
When setting a laser in constant current mode, the GAIN alarm is automatically disabled. The output
power alarm continues to function, testing for a 2 dB deviation of output power from the last output
power setpoint.
If necessary, the ALMDSBL command (see theALMDSBL” section on page 5-12) can be used to
disable the LPOUT alarm.
Note A value of zero will place the specified laser in idle mode.
Example 5-16 SETI Command:
0-0>SETI n xxx
LD n: Const Pump Crnt xxx(mA)
0-0>
0-0>SETI 1 0
0-0>
Use Table 5-10 to interpret the SETI commands.
SETOUT
Explanation:
Constant EDFA output power mode has a configuration of 75 mW constant pump power for the
first-stage pump laser and the second-stage laser controlling the overall EDFA output power. Use the
SETOUT command to set the control point for the second-stage laser. The LPOUT alarm is
automatically enabled and the GAIN alarm is automatically disabled when the SETOUT command is
successfully issued.
A value of zero for the EDFA output power setpoint puts both pumps into IDLE mode. In this case, no
control mode line is displayed after you enter the SETOUT command.
Table 5-10 Laser Diode Pump Parameters
Parameter Format Description
n 1 or 2 Laser diode pump number
xxx 0..300 Laser diode pump current setpoint in
mA. A value of zero will place the
laser in IDLE mode and will cause the
control mode line not to display.
Command: SETOUT
Syntax: SETOUT <value, decimal (0-65mW)>
Password: Yes
Configuration: Yes
Brief Description: Set EDFA in constant output power mode