Specifications
5-11
Cisco ONS 15216 EDFA Operation Guide
78-12818-01
Chapter 5 Command Line Reference
System Status Commands
Laser diode pump control modes are displayed in the same format as the LD command. The only
exception is that the note <<< Ctrl-X to Stop >>> which is printed on the same line as the first laser
diode pump's control mode.
Format fields are identical to the PRM command.
Example 5-9 STAT Command:
0-0>STAT 1
LD 1: Const Pump Crnt 10(mA) <<< Ctrl-X to Stop >>>
LD 2: Const Pump Crnt 10(mA)
LD T/To TEC LDPwr LDCrnt Amb DC In Out Gain
(C) (mA) (mW) (mA) (C) (V) (uW/dBm) (mW/dBm) (dBm)
1 25.5/25.5 39 0.49 9.92 30.25 5.2 0.0/-120.00 0.00/-90.00 30.0
VER
Example 5-10 VER Command:
0-0>VER
CISCO Optical Amplifier, ver.4.20, May 05, 00
Ser.# Q17DA1100003 Rev. B
Active Plane: 1
Inactive ver. 4.16
ALARM D to see alarms
0-0>
0-0>VER
aaaaaaaaaaaaaaaaaaaaaaaa, ver.bbbb, cccccccccc
Ser.# dddddddddddd Rev. eeeeeeeee
Active Plane: f
Inactive ver. gggg
hhhhhhhhhhhhhhhhhhhhhh
0-0>
Fixed widths are variable unless specified. Delimiters include the comma, period, pound, colon, space,
carriage return, and line feed. Use Table 5-8 to interpret the VER command details.
Command: VER
Syntax: VER
Password: N/A
Configuration: N/A
Brief
Description:
Displays general information about the EDFA
Explanation: Displays module details.