Specifications
5-7
Cisco ONS 15216 EDFA Operation Guide
78-12818-01
Chapter 5 Command Line Reference
System Status Commands
Example 5-4 ALARM D command:
0-0>ALARM D
Pump 1 Pump 2
Name Type Crnt Cnt Crnt Cnt Descr
LCRNT Minor xxxxx yyy xxxxx yyy Excessive pump crnt/pump bias
LTMP Minor xxxxx yyy xxxxx yyy LD temp out-of-range
EDFA 1
Name Type Crnt Cnt Descr
LPOUT Major xxxxx yyy Loss outp pwr
LPIN Major xxxxx yyy Loss inp pwr
GAIN Major xxxxx yyy Gain out-of-range
CTMP Major xxxxx yyy Case temp out-of-range
0-0>
Table 5-5 provides information for interpreting the results of an ALARM D command.
To clear all alarm counts, type the ALARM C command.
Example 5-5 Alarm C Command:
0-0>ALARM C
Alarms cleared
0-0>
HELP
Ta b l e 5 - 5 A l a r m s
Parameter Value Description
XXXXX Alarm Alarm is set
Dsbl Alarm is disabled
OK Alarm is cleared
YYY 0..255 Count of alarm activations.
Command: HELP
Syntax: HELP
Password: N/A
Configuration: N/A
Brief
Description:
Lists available commands
Detailed: Displays list of available user commands.