Specifications

5-4
Cisco ONS 15216 EDFA Operation Guide
78-12818-01
Chapter 5 Command Line Reference
Login Session
Type- float (f) or signed decimals (d)
Additional information regarding measurement parameters can be found in the “PRM” section on
page 5-9.
Login Session
@XY
Explanation:
To begin a command session, you need to log in to the ONS 15216 EDFA1. Typing the ’@’ character
while logged into a unit immediately terminates the command session. Table 5-2 displays the
ONS 15216 EDFA1 address parameters.
Example 5-2 @XY Command:
@xy
x-y>
Note The Default Address for the ONS 15216 EDFA1 is 00.
To begin a session, enter @xy followed by a carriage return (where xy is the address of the module). The
address of the ONS 15216 EDFA1 is a two-digit number from 00 to 99. In this document, the default
address 00 is used for the ONS 15216 EDFA1.
The ONS 15216 EDFA1 ends every command by returning the following prompt: a-b> (where ab is the
address of the ONS 15216 EDFA1). The prompt does not appear with the following commands:
CONFIG
Command: @XY
Syntax: None given
Password: N/A
Configuration: N/A
Brief Description: Login to unit with address XY
Table 5-2 EDFA Address Parameters
Parameter Format Description
x 0-9 First half of EDFA address
y 0-9 Second half of EDFA address