Specifications

3-4
Cisco ONS 15216 EDFA Operation Guide
78-12818-01
Chapter 3 Installation
Installation Commands
Installation Commands
You can connect to an ONS 15216 locally using a serial connection or remotely using a modem.
See the “Local Serial Communication Setup” section on page 4-1 and the “Remote Communication
Component Requirements” section on page 4-5 for information.
After you establish connection, use the following commands to complete the hardware installation. See
Chapter 5, “Command Line Reference” for detailed information about each of these commands.
Table 5-17 on page 5-26 summarizes all of the ONS 15216 EDFA1 commands.
Installation-Introductory Commands
You can use the following commands to first establish communication with the ONS 15216 EDFA1 and
gain access to additional information about the amplifier.
@00– Use this command to log in and establish a connection to the EDFA1. The default address for
the EDFA is “00”.
HELP– Use this command to review all of the available commands.
PASS– This command enables you to use password-protected commands. All commands which
affect system operation or alarm-threshold parameters are password protected. Prior to using any
password-protected commands, you must first enter the PASS command with the correct password.
The factory-set password is “CISCO”. See the “PASS” section on page 5-17 for information about
changing the password.
VER– This command accesses information about the ONS 15216 EDFA1 software and hardware.
After entering this command, record the identification and inventory information.
Installation-Review and Operational Commands
You can use the following commands to review the overall status of the EDFA and to make basic
configuration changes.
STAT– Review the operational status of the EDFA
SETADDR– Changes the numerical address of the 15216 EDFA1; use this command to change the
default address, “00”
ALMENBL– Enables alarm checking for a specified alarm
ALMDSBL– Disables an alarm
ALARM C– Clears alarm count
SET_LOSTH– Set, enable, disable, or display the loss-of-input signal threshold; the factory default
is set to -30 dBm
SET– Set operational modes of the ONS 15216 EDFA1; for example,
SETGT command- sets EDFA to constant gain mode temperature compensated (the factory
default)
SETI command- sets the specified pump laser to constant current mode
SETOUT command- sets EDFA to constant output power mode
SETP command- sets specified pump laser to constant output power