Specifications
3-4
Cisco ONS 15216 EDFA Operation Guide
78-12818-01
Chapter 3 Installation
Installation Commands
Installation Commands
You can connect to an ONS 15216 locally using a serial connection or remotely using a modem.
See the “Local Serial Communication Setup” section on page 4-1 and the “Remote Communication
Component Requirements” section on page 4-5 for information.
After you establish connection, use the following commands to complete the hardware installation. See
Chapter 5, “Command Line Reference” for detailed information about each of these commands.
Table 5-17 on page 5-26 summarizes all of the ONS 15216 EDFA1 commands.
Installation-Introductory Commands
You can use the following commands to first establish communication with the ONS 15216 EDFA1 and
gain access to additional information about the amplifier.
• @00– Use this command to log in and establish a connection to the EDFA1. The default address for
the EDFA is “00”.
• HELP– Use this command to review all of the available commands.
• PASS– This command enables you to use password-protected commands. All commands which
affect system operation or alarm-threshold parameters are password protected. Prior to using any
password-protected commands, you must first enter the PASS command with the correct password.
The factory-set password is “CISCO”. See the “PASS” section on page 5-17 for information about
changing the password.
• VER– This command accesses information about the ONS 15216 EDFA1 software and hardware.
After entering this command, record the identification and inventory information.
Installation-Review and Operational Commands
You can use the following commands to review the overall status of the EDFA and to make basic
configuration changes.
• STAT– Review the operational status of the EDFA
• SETADDR– Changes the numerical address of the 15216 EDFA1; use this command to change the
default address, “00”
• ALMENBL– Enables alarm checking for a specified alarm
• ALMDSBL– Disables an alarm
• ALARM C– Clears alarm count
• SET_LOSTH– Set, enable, disable, or display the loss-of-input signal threshold; the factory default
is set to -30 dBm
• SET– Set operational modes of the ONS 15216 EDFA1; for example,
–
SETGT command- sets EDFA to constant gain mode temperature compensated (the factory
default)
–
SETI command- sets the specified pump laser to constant current mode
–
SETOUT command- sets EDFA to constant output power mode
–
SETP command- sets specified pump laser to constant output power