Specifications
5-21
Cisco ONS 15216 EDFA2 Operations Guide
78-13908-02
Chapter 5 SNMP MIB Installation and Configuration
Retrieving Information
Case Temperature
Command: snmp attribute get local cerent15216EdfaPumpStatusAmbientTemp
Syntax: snmp attribute get local cerent15216EdfaPumpStatusAmbientTemp pump#
Description: Displays case temperature value (where # is the pump number).
The following commands display the temperature value (where # is the pump number) and other pump
status data:
• snmp row display local cerent15216EdfaPumpStatusAmbientTemp pump # command
The cerent15216EdfaPumpStatusAmbientTemp attribute of the cerentEdfaPumpStatusEntry display
command shows the case temperature (Example 5-11).
Example 5-11 cerent15216EdfaPumpStatusEntry Display Command
hostname:ONS15216 EDFA2> snmp row display local cerent15216EdfaPumpStatusEntry 1
CLASS cerent15216Edfa--MIB.cerent15216EdfaPumpStatusEntry ::=
{
cerent15216EdfaPumpStatusPumpNum = 1;
cerent15216EdfaPumpStatusLaserChipTemp = 260;
cerent15216EdfaPumpStatusLaserChipTempSetpoint = 260;
cerent15216EdfaPumpStatusLaserTECCurrent = 20;
cerent15216EdfaPumpStatusLaserPower = 8503;
cerent15216EdfaPumpStatusLaserCurrent = 17010;
cerent15216EdfaPumpStatusAmbientTemp = 2272;
cerent15216EdfaPumpStatusDCVoltage = 52;
cerent15216EdfaPumpStatusInPoweruW = 1;
cerent15216EdfaPumpStatusInPowerdBm = -4003;
cerent15216EdfaPumpStatusOutPowermW = 3195;
cerent15216EdfaPumpStatusOutPowerdBm = 1504;
cerent15216EdfaPumpStatusGain = 550;
};
Refer to Table 5-10 for information about all of the parameters in the cerent15216EdfaPumpStatusEntry
Table.
Temperature Alarm Threshold
CtmpMin
Command: snmp attribute get local cerent15216EdfaCtmpMin
Syntax: snmp attribute get local cerent15216EdfaCtmpMin
Description: This command displays minimum case temperature alarm threshold.