Specifications

5-16
Cisco ONS 15216 EDFA2 Operations Guide
78-13908-02
Chapter 5 SNMP MIB Installation and Configuration
Setting Up Traps
cerent15216EdfaVersionGroup Table
The cerent15216EdfaVersionGroup Table allows users to display the currently loaded image and the
image to be loaded after cutover. Table 5-13 describes cerent15216EdfaVersionGroup Table variables.
Setting Up Traps
Traps are asynchronous notifications sent from the ONS 15216 EDFA2 to a predetermined location (IP
address, subnet mask, etc.). A community entry must be created prior to remotely setting up traps using
either Telnet or a terminal server. Table 5-14 displays the alarm notification types in the
cerent15216Edfa.mib that initiate a trap.
cerent15216EdfaOpSrcFileName DisplayString (SIZE (0 to 127)) Read-write Source file name for the Load operation.
cerent15216EdfaOpTftpSrvAddr IpAddress Read-write TFTP file server address for the Load
operation.
cerent15216EdfaOpReset cerent15216EdfaAction Read-write When “perform” is written to this object, a
software reset is performed.
cerent15216EdfaOpSaveConfig cerent15216EdfaAction Read-write To save the configuration of the optical
module, write “perform” to this object.
Table 5-12 cerent15216EdfaOpGroup Variable Descriptions (continued)
Variable Syntax
Maximum
Access Description
Table 5-13 cerent15216EdfaVersionGroup
Variable Syntax
Maximum
Access Description
cerent15216EdfaCurrentVersion DisplayString
(0 to 255 characters)
Read-only The version of the currently
loaded image.
cerent15216EdfaAlternateVersion DisplayString
(0 to 255 characters)
Read-only The version of the image to be
loaded after a cutover is
performed.
Table 5-14 Notification Types that Initiate a Trap
Notification MIB Items Description
cerent15216EdfaOpFinished cerent15216EdfaOpSaveConfig
cerent15216EdfaOpCutover
cerent15216EdfaOpLoad
cerent15216EdfaOpReset
“CerentOp Finished” This trap indicates that an
operation has completed or, in the case of
cerent15216EdfaOpReset, the operation is about
to be performed.
cerent15216EdfaAlarmActivated cerent15216EdfaAlarmID
cerent15216EdfaAlarmPrioriy
cerent15216EdfaAlarmDateAndTime
Alarm Activate”A notification indicating that an
alarm has changed to an active state.
cerent15216EdfaAlarmCleared cerent15216EdfaAlarmID
cerent15216EdfaAlarmPrioriy
cerent15216EdfaAlarmDateAndTime
Alarm Cleared” A notification indicating that an
alarm has changed to a cleared state.