Specifications
5-14
Cisco ONS 15216 EDFA2 Operations Guide
78-13908-02
Chapter 5 SNMP MIB Installation and Configuration
Tables and Groups
1.
The value of the cerent15216EdfaPumpStatusGain variable should always be around 23 dB. This variable is the internal
amplifier module gain. The cerent15216EdfaPumpStatusGain variable should not be confused with the
cerent15216EdfaConstGainOverallGain variable that is used to set the gain of the ONS 15216 EDFA2.
cerent15216EdfaAlarmEntry Table
The cerent15216EdfaAlarmEntry Table is used to display alarm status. The associated table command
provides a summary of all alarms. Table 5-11describes the cerent15216EdfaAlarmEntry Table variables.
Table 5-10 cerent15216EdfaPumpStatusEntry Variable Descriptions
Variable Syntax
Maximum
Access Description
cerent15216EdfaPumpStatusPumpNum cerent15216EdfaPumpNumber Read-only Laser pump number
cerent15216EdfaPumpStatusLaserChipTemp Integer
(–9999 to 9999)
Read-only Laser chip temperature
(*10
°C)
cerent15216EdfaPumpStatusLaserChipTempSetpoint Integer
(0 to 999)
Read-only Laser chip temperature
setpoint
(*10
°C)
cerent15216EdfaPumpStatusLaserTECCurrent Integer
(0 to 99999)
Read-only Laser TEC current
(mA)
cerent15216EdfaPumpStatusLaserPower Integer
(0 to 99999)
Read-only Laser power
(*100 mW)
cerent15216EdfaPumpStatusLaserCurrent Integer
(0 to 999999)
Read-only Laser current
(*100 mA)
cerent15216EdfaPumpStatusAmbientTemp Integer
(–9999 to 9999)
Read-only Ambient temperature
(*100
°C)
cerent15216EdfaPumpStatusDCVoltage Integer
(0 to 9999)
Read-only DC voltage
(*10V)
cerent15216EdfaPumpStatusInPoweruW Integer
(0 to 99999)
Read-only Input power
(*10 microwatts)
cerent15216EdfaPumpStatusInPowerdBm Integer
(–999999 to 999999)
Read-only Input power
(*100 dBm)
cerent15216EdfaPumpStatusOutPowermW Integer
(0 to 999999)
Read-only Output power
(*100 mW)
cerent15216EdfaPumpStatusOutPowerdBm Integer
(–99999 to 99999)
Read-only Output power
(*100 dBm)
cerent15216EdfaPumpStatusGain
1
Integer
(–9999 to 9999)
Read-only Gain
(*10 dBm)