Specifications

5-13
Cisco ONS 15216 EDFA2 Operations Guide
78-13908-02
Chapter 5 SNMP MIB Installation and Configuration
Tables and Groups
cerent15216EdfaOverallControl Table
The cerent15216EdfaOverallControl Table allows the user to display and configure overall gain and
preattenuation. Table 5-9 describes cerent15216EdfaOverallControl variables.
cerent15216EdfaPumpStatusEntry
The cerent15216EdfaPumpStatusEntry Table is used to display optical amplification module data.
Table 5-10 displays information regarding the cerent15216EdfaPumpStatusEntry Table variables.
Table 5-8 cerent15216EdfaOverallStatusGroup
Variable Syntax
Maximum
Access Description
cerent15216EdfaInPoweruW Integer (0 to 99999) Read-only EDFA input power
(*10 microwatts)
cerent15216EdfaInPowerdBm Integer (–99999 to 99999) Read-only EDFA input power
(*100 dBm)
cerent15216EdfaOutPowermW Integer (0 to 999999) Read-only EDFA output power
(*100 mW)
cerent15216EdfaOutPowerdBm Integer (–999999 to
99999)
Read-only EDFA output power
(*100 dBm)
Table 5-9 cerent15216EdfaOverallControl Variable Descriptions
Variable Syntax
Maximum
Access Description
cerent15216EdfaConstGainOverallGain Integer (130 to 220) Read-write The overall gain
(*10 dBm) that is
used when the
control mode in the
PumpCfgTable is set
to constGain or
constOutputPower.
cerent15216EdfaVariableGainPreAttenu
ation
Integer (10 to 100) Read-write The preattenuation
(*10 dBm) that is
used when the
control mode in the
PumpCfgTable is
neither constGain
nor
constOutputPower.