Specifications
5-12
Cisco ONS 15216 EDFA2 Operations Guide
78-13908-02
Chapter 5 SNMP MIB Installation and Configuration
Tables and Groups
cerent15216EdfaOverallStatusGroup Table
The cerent15216EdfaOverallStatusGroup Table allows users to display the input and output of the ONS
15216 EDFA2 amplifier. Table 5-8 describes cerent15216EdfaOverallStatusGroup Table variables.
Table 5-7 cerent15216EdfaPumpCfgEntry Variable Descriptions
Variable Syntax
Maximum
Access Description
cerent15216EdfaPumpCfgPumpNum cerent15216EdfaPu
mpNumber
Not
Accessible
Laser pump number (1
or 2).
cerent15216EdfaPumpCfgControlM
ode
cerent15216EdfaC
ontrolMode
Read-write Laser pump control
mode. When the mode
is set directly to
constCurrent,
constPower, or
constOutputPower, the
current value of
ConstPumpCurrent,
ConstPumpPower, or
ConstOutPower is used
as the constant
parameter for the new
mode.
cerent15216EdfaPumpCfgConstPum
pCurrent
Integer (0 to 300) Read-write Laser pump constant
pump current (mA).
The current that is used
when the control mode
is changed to
constCurrent.
cerent15216EdfaPumpCfgConstPum
pPower
Integer (0 to 100) Read-write Laser pump constant
pump power (mW). The
power that is used when
the control mode is
changed to
constPumpPower.
cerent15216EdfaPumpCfgConstOut
Power
Integer (0 to 650) Read-write Laser pump constant
output power (*10
mW). The power that is
used when the control
mode is changed to
constOutputPower.