Specifications
5-10
Cisco ONS 15216 EDFA2 Operations Guide
78-13908-02
Chapter 5 SNMP MIB Installation and Configuration
Tables and Groups
cerent15216EdfaCfgGroup Table
The cerent15216EdfaCfgGroup Table is used to set or get alarm threshold configuration. The associated
table command provides a summary of all alarm thresholds. See Table 5-6 for variable definitions. For
more information on alarm thresholds, see the “Set Alarm Thresholds” section on page 4-4.
Table 5-6 cerent15216EdfaCfgGroup Variable Descriptions
Variable Syntax
Maximum
Access Description
cerent15216EdfaCfgSaved True Value Read-only Indicates whether the
current configuration has
been saved.
cerent15216EdfaLpoutSetpoint Integer (0 to 1000) Read-only Laser pump output power
setpoint for the Lpout alarm
(*10 mW).
This is set when the
cerent15216EdfaPumpCfgC
onstOutPower attribute is
set for pump 2.
cerent15216EdfaLpoutDeviation Integer (0 to 1000) Read-write Amount that the output
power must deviate from the
setpoint to set the Lpout
alarm (*100 dBm).
cerent15216EdfaLpoutHysteresis Integer (0 to 1000) Read-write Amount that the output
power must move towards
the setpoint before the Lpout
alarm is cleared (*100
dBm).
cerent15216EdfaLOSThreshold Integer (–3100 to
–1500)
Read-write Loss of signal threshold
(*100 dBm).
cerent15216EdfaLOSHysteresis Integer (0 to 1000) Read-write Amount above
cerent15216EdfaLOSThres
hold that the input signal
must rise before the Lpin
alarm is cleared (*100
dBm).
cerent15216EdfaCtmpMin Integer (–10 to 10) Read-write Minimum allowable case
temperature in degrees
Celsius.
cerent15216EdfaCtmpMinHystere
sis
Integer (0 to 10) Read-write Amount above
cerent15216EdfaCtmpMin
that the case temperature
must rise before the Ctmp
alarm is cleared in degrees
Celsius.
cerent15216EdfaCtmpMax Integer (20 to 70) Read-write Maximum allowable case
temperature in degrees
Celsius.