Specifications

4-10
Cisco ONS 15216 EDFA2 Operations Guide
78-13908-02
Chapter 4 Provisioning
Set Alarm Thresholds
cerent15216EdfaCt
mpMax
Integer
(20 to 70)
Read-write Notifies operations personnel
if the case temperature of the
ONS 15216 EDFA2 is at a
level that may impact proper
operation of the optical
network. Set the maximum
case temperature at a value that
is appropriate for intended
application and within product
specifications. Consult with a
Cisco Systems Engineer to
determine the threshold value
for your application. As a
guideline, Cisco recommends
that minimum case
temperature value be set at
50
°C. Valid entries are
between 20 and 70
°C.
cerent15216EdfaCt
mpMaxHysteresis
Integer
(0 to 10)
Read-write Used to set the amount the case
temperature of module must
drop below the maximum case
temperature alarm level before
the alarm is cleared. This
attribute, in conjunction with
the case temperature minimum,
enables efficient clearing of
alarms. Set the hysteresis at a
value that is appropriate for the
application. If an alarm occurs,
the case temperature must
return to 1
o
C below the set
value to clear the alarm.
Consult with a Cisco Systems
Engineer to determine the
value for your application. As a
guideline, Cisco recommends
setting the value at 1
°C. Valid
entries are between 0 and
10
°C. Setting this value to 0
disables this option.
cerent15216EdfaC
LEI
Display
String
(0 to 10
characters)
Read-only Indicates the factory setting of
the Common Language
Equipment Identifier (CLEI)
code (established by Telcordia)
of the Cisco ONS 15216
EDFA2. This attribute can be
accessed, but it cannot be
changed by the user.
Table 4-1 Alarm Threshold Attribute Definitions (continued)
Attribute Variable Definition Syntax
Maximum
Access Description