Specifications
4-6
Cisco ONS 15216 EDFA2 Operations Guide
78-13908-02
Chapter 4 Provisioning
Set Alarm Thresholds
Table 4-1 Alarm Threshold Attribute Definitions
Attribute Variable Definition Syntax
Maximum
Access Description
cerent15216EdfaCf
gSaved
Configuration Saved
Status
True Value Read-only Indicates whether the current
configuration has been saved.
The value can be true or false.
If false, the configuration is not
saved.
cerent15216EdfaL
poutSetpoint
Loss of Output
Power Setpoint
Integer
(0 to 1000)
Read-only Can be disregarded when
operating amplifier in factory
default, constant gain mode.
Setpoint object is only valid
when amplifier is used in
constant output power modes
of operation.
cerent15216EdfaL
poutDeviation
Loss of Power
Output Deviation
Integer
(0 to 1000)
Read-write Can be disregarded when
operating amplifier in factory
default, constant gain mode.
Deviation object is only valid
when amplifier is used in
constant output power modes
of operation.
cerent15216EdfaL
poutHysteresis
Loss of Power
Output Hysteresis
Integer
(0 to 1000)
Read-write Can be disregarded when
operating amplifier in factory
default, constant gain mode.
Hysteresis object is only valid
when amplifier is used in
constant output power modes
of operation.