Specifications

9-66
Cisco ONS 15216 EDFA2/EDFA2-A Operations Guide, R2.4
July 2004
Chapter 9 TL1 Commands
9.6.41 RTRV-TOD
9.6.41 RTRV-TOD
Command Types RTRV-TOD
Retrieves the date and time of the ONS 15216 EDFA2.
Syntax Description
RTRV-TOD:[<tid>]::<ctag>[::];
<sid> <date> <time>
M <ctag> COMPLD
"<tmody>,<tmtype>,<tmsrcdv>,<tmsrcst>"
;
Example 9-46 RTRV-TOD Command and Response
Amp01:ONS15216 EDFA2>
RTRV-TOD:Amp01::123;
Amp01 2002-06-20 14:30:00
threshholdtype
and
thresholdvalue
pairs
Type of threshold or set point that is to be retrieved. A null
value is equivalent to ALL. Possible to specify values for one
or more of the following:
MAXCTMP Maximum case temperature (cerent15216EdfaCtmpMax).
thresholdvalue can be between 20 and 70, with default of 70 in
units of
°C.
MAXCTMPHYST Maximum case temperature hysteresis
(cerent15216EdfaCtmpMaxHysteresis).
thresholdvalue can be between 0 and 10, with default of 1, in
units of
°C.
MINCTMP Minimum case temperature (cerent15216EdfaCtmpMin).
thresholdvalue can be between –10 and 10, with default of –5,
in units of
°C.
MINCTMPHYST Minimum case temperature hysteresis
(cerent15216EdfaCtmpMinHysteresis).
thresholdvalue can be between 0 and 10, with default of 1, in
units of
°C.
PWRBUSMIN Power bus minimum voltage
(cerent15216EdfaPowerBusDCVoltageMin).
thresholdvalue can be between 350 and 700, with default of
420, in units of –10 VDC.
PWRBUSMAX Power bus maximum voltage
(cerent15216EdfaPowerBusDCVoltageMax).
thresholdvalue can be between 350 and 700, with default of
570, in units of –10 VDC.
Table 9-46 RTRV-TH-EQPT Syntax Description (continued)
Parameter Syntax Description