Specifications

9-49
Cisco ONS 15216 EDFA2/EDFA2-A Operations Guide, R2.4
July 2004
Chapter 9 TL1 Commands
9.6.29 RTRV-COND-ALL
9.6.29 RTRV-COND-ALL
Command Types RTRV-COND-ALL
Generates a report on the condition (state) of all alarms and standing conditions.
Note The messages for Loss of Signal (LOS), Gain Out of Range (GAIN), and Loss of Output Power
(LPOUT) are prioritized (in the order just listed) so that only one message can be delivered at one time.
For example, if the ONS 15216 EDFA2 detects both a loss of input signal and a loss of output power at
the same time, it will deliver only the Loss of Signal (LOS) message to the user. This prioritized filtering
of alarms does not occur with the SNMP delivery of alarms of the ONS 15216 EDFA2.
condtype Condition type identifies the type of alarm (maps to
cerent15216EdfaLogEventID). Possible condtype and
corresponding conddescr (in quotes) are:
CTMP “Case Temperature Out of Range” alarm
(cerent15216EdfaAlarmCtmp).
DBBACKUP “Database Backup In Progress”
(cerent15216EdfaOpDbBackup).
DBRESTORE “Database Restore In Progress”
(cerent15216EdfaOpDbRestore).
LCRNT1 “Excessive Pump1 Current” alarm
(cerent15216EdfaAlarmLcrnt1).
LCRNT2 “Excessive Pump2 Current” alarm
(cerent15216EdfaAlarmLcrnt2).
LTMP1 “Excessive Pump1 Temperature” alarm
(cerent15216EdfaAlarmLtmp1).
LTMP2 “Excessive Pump2 Temperature” alarm
(cerent15216EdfaAlarmLtmp2).
PWRBUSA “Power Bus A (voltage) Alarm”
(cerent15216EdfaAlarmPowerBusA).
PWRBUSB “Power Bus B (voltage) Alarm”
(cerent15216EdfaAlarmPowerBusB).
SFTWDOWN “Software Download In Progress” (cerent15216EdfaOpLoad).
ALL Any or all of the above.
NULL Defaults to ALL.