Specifications

9-38
Cisco ONS 15216 EDFA2/EDFA2-A Operations Guide, R2.4
July 2004
Chapter 9 TL1 Commands
9.6.22 RTRV-ALM-ALL
Syntax Description RTRV-ALM-ALL:[<tid>]::<ctag>::[<ntfcncde>],[<condtype>],[<srveff>][,,,,,];
<sid> <date> <time>
M <ctag> COMPLD
"<aid>,<ccm>:<ntfcncde>,<condtype>,<srveff>,<ocrdat>,<ocrtm>,,:<conddescr>"
;
Example 9-26 RTRV-ALM-ALL Command and Response
Amp01:ONS15216 EDFA2>
RTRV-ALM-ALL:Amp01::229::MN,LCRNT1,NSA,,;
Amp01 2002-06-20 14:30:00
M 229 COMPLD
"1,DWDM:MJ,LOS,SA,6-20,14-25-30,,:\"Loss Of Signal\""
"EQPT,EQPT:MN,LCRNT1,NSA,6-20,14-25-30,,:\"Excessive Pump1 Current\""
;
Table 9-28 RTRV-ALM-ALL Syntax Description
Parameter Syntax Description
aid Possible values are:
1 Directly affecting the optical signal
EQPT General parameters of the ONS 15216 EDFA2 (not directly
affecting optical signal).
PWR-A
Affecting Power Bus A.
PWR-B
Affecting Power Bus B.
conddescr Detailed text description of the event. The conddescr is 1 to 64
characters of ASCII text. See condtype below