Specifications
9-29
Cisco ONS 15216 EDFA2/EDFA2-A Operations Guide, R2.4
July 2004
Chapter 9 TL1 Commands
9.6.18 REPT ALM DWDM
Example 9-19 INIT-SYS Command
Amp01:ONS15216 EDFA2>
INIT-SYS:Amp01:ALL:1234::1;
9.6.18 REPT ALM DWDM
Command Types REPT ALM DWDM
Reports when a DWDM alarm is logged or cleared (derived from cerent15216EdfaAlarmState).
Note The REPT ALM DWDM messages for Loss of Signal, Gain Out of Range, and Loss of Output Power
are prioritized (in the order just listed) so that only one message can be delivered at one time. For
example, if the ONS 15216 EDFA2 detects both a loss of input signal and a loss of output power at the
same time, it will deliver only the Loss of Signal message to the user. This prioritized filtering of alarms
does not occur with the SNMP delivery of alarms of the ONS 15216 EDFA2.
Syntax Description
<sid> <date> <time>
<almcde> <atag> REPT ALM DWDM
"<aid>:<ntfcncde>,<condtype>,<srveff>,<ocrdat>,<ocrtm>,,:<conddescr>"
;
Example 9-20 REPT ALM DWDM Message
Amp01 2001-06-18 14:50:44
** 142 REPT ALM DWDM
"1:MJ,LOS,SA,6-18,14-50-44,,:\"Loss Of Signal\""
;
Ta b l e 9 - 2 3 I N I T- SYS S y n t a x D e s c ri p t i o n
Parameter Syntax Description
aid
string
EQPT
ALL
EQPT and ALL have same input effect.
ph
integer
1
Level of initialization. Always 1.
Table 9-24 REPT ALM DWDM Syntax Description
Parameter Syntax Description
time hh:mm:ss Time of origination of TL1 message.