Specifications

8-10
Cisco ONS 15216 EDFA2/EDFA2-A Operations Guide, R2.4
July 2004
Chapter 8 Provisioning with TL1
8.8 Set Alarm Thresholds
MINCTMP Minimum
case
temperature
Integer
(–10 to 10,
–5 default)
Read-write Alarm notifies operations personnel if
the case temperature of the ONS 15216
EDFA2 drops below a level that
impacts proper operation of the optical
network. The minimum case
temperature should be set at a value
that is appropriate for the intended
application and within product
specifications. Consult with the Cisco
TAC to determine the correct value for
your application. As a guideline, Cisco
recommends that minimum case
temperature be set at 1
°C. Valid entries
are between –10 and 10
°C.
MINCTMPHYST Minimum
case
temperature
hysteresis
Integer
(0 to 10,
1 default)
Read-write Used to set the amount that the case
temperature of the module must rise
above the minimum case temperature
alarm level before the alarm is cleared.
Set the hysteresis at a value that is
appropriate for the application so that
the alarm condition clears when the
input is stable. Consult with the Cisco
TAC to determine the correct value for
your application. As a guideline, Cisco
recommends that the hysteresis value
be set at 1
°C. Valid entries are between
0 and 10
°C. Setting this value to 0
disables this option.
Table 8-1 Alarm Threshold Attribute Definitions (continued)
Attribute
Variable
Definition Syntax
Maximum
Access Description