Chapter 5 Troubleshooting the Uplink Cards
Troubleshooting the POS Uplink Card Installation
• STS Path Loss-of-Pointer (LOP)
• STS Path Alarm Indication Signal (AIS)
• STS Path Remote Defect Indication (RDI)
• B1 Bit Error Rate (BER) threshold crossing alarm (b1-tca)
• B2 BER threshold crossing alarm (b2-tca)
• B3 BER threshold crossing alarm (b3-tca)
• Line Bit Interleave Parity (LBIP) BER in excess of signal degrade threshold (sd-ber)
• LBIP BER in excess of signal failure threshold (sf-ber)
At any time the status of the SONET/SDH alarm and signal events can be examined using the show
controllers command, as shown in the following example:
Router# show controllers pos1/1
Interface POS1/1
Hardware is OC48 POS
SECTION
LOF = 0 LOS = 0 BIP(B1) = 0
LINE
AIS = 0 RDI = 0 FEBE = 0 BIP(B2) = 0
PATH
AIS = 0 RDI = 0 FEBE = 0 BIP(B3) = 0
LOP = 0 NEWPTR = 0 PSE = 0 NSE = 0
Active Defects: None
Active Alarms: None
Alarm reporting enabled for: SF SLOS SLOF B1-TCA B2-TCA PLOP B3-TCA
Framing: SONET
APS
COAPS = 0 PSBF = 0
State: PSBF_state = FALSE
ais_shut = FALSE
Rx(K1/K2): 00/00 S1S0 = 00, C2 = CF
Remote aps status non-aps; Reflected local aps status non-aps
CLOCK RECOVERY
RDOOL = 0
State: RDOOL_state = FALSE
PATH TRACE BUFFER : STABLE
Remote hostname : RouterB
Remote interface: POS1/0
Remote IP addr : 2.2.2.1
Remote Rx(K1/K2): 00/00 Tx(K1/K2): 00/00
BER thresholds: SF = 10e-4 SD = 10e-6
TCA thresholds: B1 = 10e-6 B2 = 10e-6 B3 = 10e-6
OPTICS
RX readout values: -6 dBm