Configuring Enhanced Object Tracking Features
Object tracking of IP SLAs operations allows clients to track the output from IP SLAs objects and use 
this information to trigger an action. Every IP SLAs operation maintains an SNMP operation return-code 
value, such as OK or OverThreshold, that can be interpreted by the tracking process. You can track two 
aspects of IP SLAs operation: state and reachability. For state, if the return code is OK, the track state is 
up; if the return code is not OK, the track state is down. For reachability, if the return code is OK or 
OverThreshold, reachability is up; if not OK, reachability is down.
Beginning in privileged EXEC mode, follow these steps to track the state of an IP SLAs operation or the 
reachability of an IP SLAs IP host:
This example shows how to configure and display IP SLAs state tracking:
Switch(config)# track 2 200 state
Switch(config)# end
Switch# show track 2
Track 2
 Response Time Reporter 1 state
 State is Down
 1 change, last change 00:00:47
 Latest operation return code: over threshold
 Latest RTT (millisecs) 4
 Tracked by:
 HSRP Ethernet0/1 3
Command Purpose
Step 1
configure terminal Enter global configuration mode.
Step 2
track object-number rtr 
operation-number state 
Enter tracking configuration mode to track the state of an IP SLAs operation.
  • The object-number range is from 1 to 500.
  • The operation-number range is from 1 to 2147483647.
Step 3
delay {up seconds [down seconds] | 
[up seconds] down seconds}
(Optional) Specify a period of time in seconds to delay communicating state 
changes of a tracked object. The range is from 1 to 180 seconds.
Step 4
exit Return to global configuration mode.
Step 5
track object-number rtr 
operation-number reachability 
Enter tracking configuration mode to track the reachability of an IP SLAs IP 
host. 
  • The object-number range is from 1 to 500.
  • The operation-number range is from 1 to 2147483647.
Step 6
delay {up seconds [down seconds] | 
[up seconds] down seconds}
(Optional) Specify a period of time in seconds to delay communicating state 
changes of a tracked object. The range is from 1 to 180 seconds.
Step 7
end Return to privileged EXEC mode.
Step 8
show track object-number Display tracking information to verify the configuration.
Step 9