Universal Broadband Router Hardware Installation Guide

A-2
Cisco uBR10012 Universal Broadband Router Hardware Installation Guide
OL-18259-01
Appendix A Technical Specifications
Cisco uBR10012 Chassis and Chassis Components
DC Power entry modules
(PEM)
Power supply monitoring
cable
Supports two separate input
feeds (–48 to –60VDC) by
means of built-in two-position
terminal blocks.
Part Number: UBR10-PWR-DC (Primary)
Part Number: UBR10-PWR-DC\R (Redundant)
Part Number: UBR10-PWR-MON-CAB
Part Number: UBR10-PWR-MON-CAB= (Spare)
Dimensions
Height: 19.25 in (48.894 cm)
Width: 6 in. (15.24 cm)
Depth: 5 in. (12.4 cm)
Weight: 10 lbs. (4.54 kg)
DC input voltage
-48 to -60 VDC nominal
-40.5 to -72 VDC minimum to maximum
DC input current: 48 A@ -48 VDC
Heat dissipation: 360 Btu1/hr.
Power consumption: 2400W maximum (8189BTU
3
)
MTBF:150,00 hours minimum
Temperature range
Operating: 41\xb0 F to 104\xb0 F (5\xb0 C to 40\xb0 C)
Storage: -40\xb0 F to 158\xb0 F (-40\xb0 C to 70\xb0 C)
AC PEM
100—120 VAC operation is
not supported
Part Number: UBR10-PWR-AC (Primary)
Part Number: UBR10-PWR-AC\R (Redundant)
Part Number: UBR10-PWR-AC= (Spare)
Dimensions:
Height: 19.25 in. (48.894 cm)
Width: 6 in. (15.24 cm)
Depth: 5 in. (12.4 cm)
Weight: 14.7 lbs (6.65 kg)
AC input voltage rating: 200-240 VAC @ 50/60Hz
AC operating voltage rating: 180-255 VAC @ 50/60Hz
AC input current rating: 13 A
DC output voltage: -54 VDC maximum
DC output current: 45.3 A maximum
Power consumption: 2650W maximum
MTBF:150,000 - minimum
Heat dissipation: 8200 Btu1/hr.
Temperature range
Operating: 23 to 122\xb0 F (-5 to 50\xb0 C)
Storage: -13 to 158\xb0 F (-25 to 70\xb0 C)
Table A-1 Cisco uBR10012 Router and Router Components Physical Specifications (continued)
Description Specifications