Universal Broadband Router Hardware Installation Guide

5-5
Cisco uBR10012 Universal Broadband Router Hardware Installation Guide
OL-18259-01
Chapter 5 Maintaining the Cisco uBR10012 Router
Replacing the Air Filter
Replacing the Air Filter
If the air filter is dirty or clogged, the fan assembly module could have a problem providing sufficient
cooling airflow throughout the chassis, causing the system to overheat. To prevent a potential
overheating problem, you should replace the air filter approximately every 6 to 12 months, depending
on how clean and dust-free your operating environment is normally. In certain environments where the
air quality is poor, you may have to replace the filter more frequently.
Note The product order number for a replacement air filter is UBR10-FAN-FILTER=.
Use the following procedure to replace the air filter:
Step 1 Remove the front cover (see “Removing the Front Cover”).
Step 2 Slide the air filter out of its slot.
Step 3 Discard the old filter.
Figure 5-3 Removing and Inserting the Air Filter
Step 4 Position the new air filter above the tabs on the inside of the bezel and slide it down into the slot. When
fully inserted, it should appear as shown in
Figure 5-4.
56393