User's Manual

1.744 1.852
Server /sensor #
Viewing Current Sensors
Procedure
PurposeCommand or Action
Enters sensor command mode.Server# scope sensor
Step 1
Displays current sensor statistics for the server.Server /sensor # show current [detail]
Step 2
This example displays current sensor statistics:
Server# scope sensor
Server /sensor # show current
Name Sensor Status Reading Units Min. Warning Max. Warning
Min. Failure Max. Failure
------------------------- -------------- ---------- ---------- ------------ ------------
------------ ------------
VR_P2_IMON Normal 16.00 AMP N/A 147.20
N/A 164.80
VR_P1_IMON Normal 27.20 AMP N/A 147.20
N/A 164.80
Server /sensor #
Viewing Storage Sensors
Procedure
PurposeCommand or Action
Enters chassis command mode.Server# scope chassis
Step 1
Displays storage sensor information.Server /chassis # show hdd [detail]
Step 2
The displayed fields are described in the following table:
DescriptionName
The name of the storage device.Name column
A brief description of the storage device status.Status column
Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5
52 OL-28893-01
Viewing Server Sensors
Viewing Current Sensors