User's Manual
This example displays temperature sensor statistics:
Server# scope sensor
Server /sensor # show temperature
Name Sensor Status Reading Units Min. Warning Max. Warning
Min. Failure Max. Failure
------------------------- -------------- ---------- ---------- ------------ ------------
------------ ------------
IOH_TEMP_SENS Normal 32.0 C N/A 80.0
N/A 85.0
P2_TEMP_SENS Normal 31.0 C N/A 80.0
N/A 81.0
P1_TEMP_SENS Normal 34.0 C N/A 80.0
N/A 81.0
DDR3_P2_D1_TMP Normal 20.0 C N/A 90.0
N/A 95.0
DDR3_P1_A1_TMP Normal 21.0 C N/A 90.0
N/A 95.0
FP_AMBIENT_TEMP Normal 28.0 C N/A 40.0
N/A 45.0
Server /sensor #
Viewing Voltage Sensors
Procedure
PurposeCommand or Action
Enters sensor command mode.Server# scope sensor
Step 1
Displays voltage sensor statistics for the
server.
Server /sensor # show voltage [detail]
Step 2
This example displays voltage sensor statistics:
Server# scope sensor
Server /sensor # show voltage
Name Sensor Status Reading Units Min. Warning Max. Warning
Min. Failure Max. Failure
------------------------- -------------- ---------- ---------- ------------ ------------
------------ ------------
P3V_BAT_SCALED Normal 3.022 V N/A N/A
2.798 3.088
P12V_SCALED Normal 12.154 V N/A N/A
11.623 12.331
P5V_SCALED Normal 5.036 V N/A N/A
4.844 5.157
P3V3_SCALED Normal 3.318 V N/A N/A
3.191 3.381
P5V_STBY_SCALED Normal 5.109 V N/A N/A
4.844 5.157
PV_VCCP_CPU1 Normal 0.950 V N/A N/A
0.725 1.391
PV_VCCP_CPU2 Normal 0.891 V N/A N/A
0.725 1.391
P1V5_DDR3_CPU1 Normal 1.499 V N/A N/A
1.450 1.548
P1V5_DDR3_CPU2 Normal 1.499 V N/A N/A
1.450 1.548
P1V1_IOH Normal 1.087 V N/A N/A
1.068 1.136
P1V8_AUX Normal 1.773 V N/A N/A
Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5
OL-28893-01 51
Viewing Server Sensors
Viewing Voltage Sensors