User's Manual
CHAPTER 5
Viewing Server Sensors
This chapter includes the following sections:
•
Viewing Power Supply Sensors, page 49
•
Viewing Fan Sensors, page 50
•
Viewing Temperature Sensors, page 50
•
Viewing Voltage Sensors, page 51
•
Viewing Current Sensors, page 52
•
Viewing Storage Sensors, page 52
Viewing Power Supply Sensors
Procedure
PurposeCommand or Action
Enters sensor command mode.Server# scope sensor
Step 1
Displays power supply sensor statistics for the
server.
Server /sensor # show psu [detail]
Step 2
Displays power supply redundancy sensor status
for the server.
Server /sensor # show psu-redundancy
[detail]
Step 3
This example displays power supply sensor statistics:
Server# scope sensor
Server /sensor # show psu
Name Sensor Status Reading Units Min. Warning Max. Warning
Min. Failure Max. Failure
-------------------- -------------------- ---------- ---------- ---------------
--------------- --------------- ---------------
PSU1_STATUS Normal present
Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5
OL-28893-01 49