User's Manual
Product ID Battery Status Cache Memory Size
---- -------------- -------------- --------------
LSI Logic fully charged 0 MB
Server /chassis #
This example displays battery backup unit information for the storage card named SAS:
Server# scope chassis
Server /chassis # scope storageadapter SAS
Server /chassis/storageadapter # show bbu
Controller Battery Type Battery Present Voltage Current Charge Charging State
---------- ------------ --------------- ---------- ---------- ------ --------------
SAS iBBU true 4.051 V 0.000 A 100% fully charged
Server /chassis/storageadapter #
Viewing the Flexible Flash Controller Properties
Before You Begin
•
Cisco Flexible Flash must be supported by your platform.
Procedure
PurposeCommand or Action
Enters the chassis command mode.Server# scope chassis
Step 1
(Optional) Displays the available Cisco Flexible
Flash controllers.
Server /chassis # show flexflash [detail]
Step 2
Enters the Cisco Flexible Flash controller command
mode for the specified controller. At this time, the
only permissible index value is FlexFlash-0.
Server /chassis # scope flexflash index
Step 3
Displays the operational profile properties.Server /chassis/flexflash # show
operational-profile [detail]
Step 4
This example displays the properties of the flash controller:
Server# scope chassis
Server /chassis # show flexflash
Controller Product Name Has Error Firmware Version Vendor Internal State
------------ ---------------- ---------- ----------------- -------- ---------------
FlexFlash-0 Cisco FlexFlash No 1.2 build 247 Cypress Connected
Server /chassis # scope flexflash FlexFlash-0
Server /chassis # show operational-profile
Primary Member Slot I/O Error Threshold Host Accessible VDs
-------------------- -------------------- --------------------
slot1 100 SCU Drivers
Server /chassis/flexflash #
Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5
42 OL-28893-01
Viewing Server Properties
Viewing the Flexible Flash Controller Properties