User's Manual

While the activation is in progress, do not:Important
Reset, power off, or shut down the server.
Reboot or reset CIMC.
Activate any other firmware.
Export technical support or configuration data.
Procedure
PurposeCommand or Action
Enters the CIMC command mode.Server# scope cimc
Step 1
Enters the firmware command mode.Server /cimc # scope firmware
Step 2
Displays the available firmware images and
status.
Server /cimc/firmware # show detail
Step 3
Activates the selected image. If no image number
is specified, the server activates the currently
inactive image.
Server /cimc/firmware # activate [1 | 2]
Step 4
The BMC reboots, terminating all CLI and GUI
sessions until the reboot completes.
At the prompt, enter y to activate the
selected firmware image.
Step 5
(Optional)
Log back into the CLI and repeat steps 13
to verify the activation.
Step 6
This example activates firmware image 1 and then verifies the activation after the BMC reboots:
Server# scope cimc
Server /cimc # scope firmware
Server /cimc/firmware # show detail
Firmware Image Information:
Update Stage: NONE
Update Progress: 100
Current FW Version: 1.3(3a)
FW Image 1 Version: 1.4(3j)
FW Image 1 State: BACKUP INACTIVATED
FW Image 2 Version: 1.3(3a)
FW Image 2 State: RUNNING ACTIVATED
Boot-loader Version: 1.4(3.21).18
Server /cimc/firmware # activate 1
This operation will activate firmware 1 and reboot the BMC.
Continue?[y|N]y
.
.
-- BMC reboot --
.
.
-- Log into CLI as Admin --
Server# scope cimc
Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5
OL-28893-01 161
CIMC Firmware Management
Activating Installed CIMC Firmware