User's Manual
Platform Event FilterID
Temperature Critical Assert Filter1
Temperature Warning Assert Filter2
Voltage Critical Assert Filter3
Current Assert Filter4
Fan Critical Assert Filter5
Processor Assert Filter6
Power Supply Critical Assert Filter7
Power Supply Warning Assert Filter8
Power Supply Redundancy Lost Filter9
Discrete Power Supply Assert Filter10
Memory Assert Filter11
Drive Slot Assert Filter12
Procedure
PurposeCommand or Action
Enters the fault command mode.Server# scope fault
Step 1
Enters the platform event filter command mode for the
specified event.
Server /fault # scope pef id
Step 2
See the Platform Event Filter table for event ID numbers.
Selects the desired system action when this event occurs. The
action can be one of the following:
Server /fault/pef # set action
{none | reboot | power-cycle |
power-off}
Step 3
• none —No system action is taken.
• reboot —The server is rebooted.
• power-cycle —The server is power cycled.
• power-off —The server is powered off.
Enables or disables the sending of a platform event alert for
this event.
Server /fault/pef # set send-alert
{yes | no}
Step 4
Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5
OL-28893-01 151
Configuring Platform Event Filters
Configuring Platform Event Filters