User's Manual
Procedure
PurposeCommand or Action
Enters the chassis command mode.Server# scope chassis
Step 1
Enters command mode for an installed storage
card.
Server /chassis # scope storageadapter slot
Step 2
Enter the battery backup unit command mode.Server /chassis/storageadapter # scope bbu
Step 3
Starts the learn cycle for the battery.Server /chassis/storageadapter #
start-learn-cycle
Step 4
This example shows how to initiate the learn cycles for a battery:
Server # scope chassis
Server /chassis # scope storageadapter SLOT-2
Server /chassis/storageadapter # scope bbu
Server /chassis/storageadapter/bbu # start-learn-cycle
Server /chassis/storageadapter/bbu #
Toggling the Locator LED for a Physical Drive
Before You Begin
You must be logged in as an admin to perform this task.
Procedure
PurposeCommand or Action
Enters the chassis command mode.Server# scope chassis
Step 1
Enters command mode for an installed
storage card.
Server /chassis # scope storageadapter slot
Step 2
Enters the physical drive command mode.Server /chassis/storageadapter # scope
physical-drive 3
Step 3
Enables or disables the physical drive locator
LED.
Server /chassis/storageadapter/physical-drive
# locator-led {on | off}
Step 4
This example shows how to enable the locator LED for physical drive 3:
Server # scope chassis
Server /chassis # scope storageadapter SLOT-2
Server /chassis/storageadapter # scope physical-drive 3
Server /chassis/storageadapter/physical-drive # locator-led on
Server /chassis/storageadapter/physical-drive* # commit
Server /chassis/storageadapter/physical-drive #