user manual

When you configure Set Startup Version Only for an I/O module, the I/O module is rebooted when the
fabric interconnect in its data path is rebooted. If you do not configure Set Startup Version Only for an
I/O module, the I/O module reboots and disrupts traffic. In addition, if Cisco UCS Manager detects a
protocol and firmware version mismatch between the fabric interconnect and the I/O module, Cisco UCS
Manager automatically updates the I/O module with the firmware version that matches the firmware in
the fabric interconnect and then activates the firmware and reboots the I/O module again.
Caution
Outage Impacts of Direct Firmware Upgrades
When you perform a direct firmware upgrade on an endpoint, you can disrupt traffic or cause an outage in
one or more of the endpoints in the Cisco UCS domain.
Outage Impact of a Fabric Interconnect Firmware Upgrade
When you upgrade the firmware for a fabric interconnect, you cause the following outage impacts and
disruptions:
The fabric interconnect reboots.
The corresponding I/O modules reboot.
Outage Impact of a Cisco UCS Manager Firmware Upgrade
A firmware upgrade to Cisco UCS Manager causes the following disruptions:
Cisco UCS Manager GUI—All users logged in to Cisco UCS Manager GUI are logged out and their
sessions ended.
Any unsaved work in progress is lost.
Cisco UCS Manager CLI—All users logged in through telnet are logged out and their sessions ended.
Outage Impact of an I/O Module Firmware Upgrade
When you upgrade the firmware for an I/O module, you cause the following outage impacts and disruptions:
For a standalone configuration with a single fabric interconnect, data traffic is disrupted when the I/O
module reboots. For a cluster configuration with two fabric interconnects, data traffic fails over to the
other I/O module and the fabric interconnect in its data path.
If you activate the new firmware as the startup version only, the I/O module reboots when the
corresponding fabric interconnect is rebooted.
If you activate the new firmware as the running and startup version, the I/O module reboots immediately.
An I/O module can take up to ten minutes to become available after a firmware upgrade.
Outage Impact of a CIMC Firmware Upgrade
When you upgrade the firmware for a CIMC in a server, you impact only the CIMC and internal processes.
You do not interrupt server traffic. This firmware upgrade causes the following outage impacts and disruptions
to the CIMC:
Cisco UCS Manager GUI Configuration Guide, Release 2.0
196 OL-25712-04
Firmware Upgrades