Router Installation and Configuration Guide
9-17
Cisco SCE8000 Installation and Configuration Guide, Rel 3.1.7
OL-16478-02
Chapter 9 Removal and Replacement Procedures
Removing and Replacing Modules
Step 10 While pressing down, simultaneously close the left and right ejector levers to fully seat the module in
the backplane connector. The ejector levers are fully closed when they are flush with the module
faceplate. (See Figure 9-13)
Note Failure to fully seat the module in the backplane connector can result in incorrect operation and/or error
messages.
Figure 9-13 Ejector Lever Closure
Step 11 Tighten the two captive installation screws on the module.
Note Make sure the ejector levers are fully closed before tightening the captive installation screws.
Removing a Module
Before you remove an SCE8000-SCM, you should first save the current configuration, if the current
configuration should be preserved and duplicated on the new SCE8000-SCM-E. (Use the copy
running-config startup-config command.) This step saves time when bringing the module back online,
if the configuration will remain the same or similar. You can recover the configuration by downloading
it from the server to the nonvolatile memory of the SCE8000-SCM-E.
Tip When you install a new SCE8000-SCM-E, check the factory default configuration; you might need to
reconfigure the system to your requirements. You can reconfigure the SCE8000-SCM-E manually, or if
you previously uploaded the original configuration to a server, you can download it to the new
SCE8000-SCM-E.
270909
FA
N
STATUS
S
C
M
1
S
C
M
2
S
I
P
3
4
S
CE
8
000-F
AN
S
Y
S
T
E
M
POW
E
R
OP
T
IC
AL
BY
PAS
S
S
T
A
T
U
S
AUX
P
O
R
T
2
L
I
N
K
A
CT
IV
E
M
A
ST
E
R
SC
E
8
0
0
0
E
X
T
EN
D
ED
S
E
RVICE C
O
N
T
R
O
L
M
O
D
ULE
OP
TI
CA
L
B
Y
P
A
S
S
OP
TI
C
A
L
BYPAS
S
CON
S
O
LE
1
0
1
00
1
0
0
0
L
I
NK
A
CT
I
V
E
P
O
R
T
1
A
C
A
B
C
D
B
D
STA
TUS
C
TR
L
O
PB-SCE8K-MM
OPT
ICA
L
BYPA
S
S1
TX
RX
TX
R
X
TX
RX
TX
R
X
A
C
A
B
C
D
B
D
S
T
A
TU
S
CT
RL
O
PB
-
SCE
8
K
-M
M
OP
T
ICA
L
BY
P
ASS
2
T
X
RX
T
X
R
X
T
X
RX
TX
RX
S
Y
ST
E
M
P
OW
E
R
OP
T
IC
A
L
BY
PAS
S
S
T
A
T
U
S
A
U
X
PO
RT
2
10
100
1000
LIN
K
A
C
TI
VE
M
A
STER
SC
E8
0
0
0
EXT
EN
D
ED S
ER
VICE C
O
N
T
R
O
L M
OD
UL
E
SCE
80
0
0
-
S
C
M-
E
SCE
80
0
0
-
S
C
M-
E
SC
E80
0
0-
S
IP
CON
S
O
LE
1
0
1
00
1
0
0
0
L
I
NK
A
CT
I
V
E
P
O
R
T
1
OP
TI
CA
L
B
Y
P
A
S
S
O
P
T
I
C
A
L
B
YP
AS
S
STAT
U
S
ACTIVE/LI
N
K
S
PA
-1
X1
0
G
E-
L
-V
2
S
T
AT
U
S
ACTIVE/LI
N
K
SP
A
-1
X1
0
G
E-
L
-V
2
STAT
U
S
ACTIVE/
L
I
N
K
S
PA
-1
X
1
0
G
E-
L
-V
2
STAT
U
S
ACTIVE/
L
I
N
K
S
PA
-1
X
1
0
G
E-
L
-V
2
10
100
1000
Ejector levers flush
with module faceplate