Network Router User Manual

13-9
Cisco 7304 Router Modular Services Card and Shared Port Adapter Software Configuration Guide
OL-4807-02
Chapter 13 Configuring the 2-Port and 4-Port T3/E3 SPAs
Configuration Tasks
Router(config-if)# mdl [string {eic | fic |
generator | lic | pfi | port | unit} string}] |
[transmit {idle-signal | path | test-signal}]
Configures the Maintenance Data Link (MDL)
message.
eic string—Equipment identification code (up
to 10 characters), which is a value used to
describe a specific piece of equipment
according to ANSI T1.107-1995.
fic string—Frame identification code (up to 10
characters), which is a value used to identify
where the equipment is located within a
building at a given location according to ANSI
T1.107-1995.
generator string—Specifies the Generator
number string sent in the MDL Test Signal
message; can be up to 38 characters.
lic string—Location identification code (up to
11 characters), which is a value used to
describe a specific location according to ANSI
T1.107-1995.
pfi string—Specifies the Path Facility
Identification Code sent in the MDL Path
message; can be up to 38 characters.
port string—Specifies the Port number string
sent in the MDL Idle Signal message; can be
up to 38 characters.
unit string—Unit identification code (up to 6
characters), which is a value that identifies the
equipment location within a subslot according
to ANSI T1.107-1995.
transmit idle-signal—Enables transmission
of the MDL idle signal message. An MDL idle
signal message, as defined by ANSI T1.107, is
distinguished from path and test signal
messages in that it contains a port number as
its final data element.
transmit path—Enables transmission of the
MDL path message. An MDL path message,
as defined by ANSI T1.107, is distinguished
from idle and test signal messages in that it
contains a facility identification code as its
final data element.
transmit test-signal—Enables transmission
of the MDL test signal message. An MDL test
signal message, as defined by ANSI T1.107, is
distinguished from path and idle signal
messages in that it contains a generator
number as its final data element.
Command Purpose