DLP- F335 Preprovision an SFP
DLP-F335 Preprovision an SFP
Note If you preprovision a multirate SFP, you must next select the line rate using the “DLP-F390 Provision
an Optical Line Rate and Wavelength” task on page 18-103.
Step 1 Complete the “DLP-F181 Log into CTC” task on page 16-34 to log into an ONS 15600 SDH on the
network.
Step 2 Click the Alarms tab:
a. Verify that the alarm filter is not turned on. See the “DLP-F288 Disable Alarm Filtering” task on
page 17-78 as necessary.
b. Verify that no unexplained conditions appear on the network. If unexplained conditions appear,
resolve them before continuing. Refer to the Cisco ONS 15600 SDH Troubleshooting Guide for
procedures to clear alarms.
c. Complete the “DLP-F379 Export CTC Data” task on page 18-88 to export alarm and condition
information.
Step 3 In node view, double-click the ASAP card where you want to provision PPM settings.
Step 4 Click the Provisioning > Pluggable Port Modules tabs.
Step 5 In the Pluggable Port Modules pane, click Create. The Create PPM dialog box appears.
Step 6 In the Create PPM dialog box, complete the following:
• PPM—Click the slot number where you want to preprovision the SFP from the drop-down list.
• PPM Type—Click the number of ports supported by your SFP from the drop-down list. If only one
port is supported, PPM (1 port) is the only option.
Step 7 Click OK. The newly created port appears on the Pluggable Port Modules pane. The row on the
Pluggable Port Modules pane turns light blue and the Actual Equipment Type column lists the
preprovisioned PPM as unknown until the actual SFP is installed. After the SFP is installed, the row on
the pane turns white and the column lists the equipment name.
Step 8 Verify that the PPM appears in the list on the Pluggable Port Modules pane. If it does not, repeat
Steps 5 through 8.
Step 9 On the Provisioning tab, click the Line subtab. If applicable for the PPM you are preprovisioning, use
the Reach and Wavelength columns to configure these parameters as needed.
Purpose This procedure preprovisions Small Form-factor Pluggables (SFPs), which
are referred to as pluggable port modules (PPMs) in CTC. Cisco-approved
STM-1, STM-4, STM-16, Ethernet, and multirate PPMs are compatible
with the ONS 15600 SDH. See the Cisco ONS 15600 SDH Reference
Manual for a list of acceptable SFPs.
Tools/Equipment None
Prerequisite Procedures None
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Provisioning or higher