Cisco ONS 15600 SDH Procedure Guide, R8.0
October 2007
Chapter 18 DLPs F300 to F399
DLP- F393 Change Threshold Settings for STM-N Ports
Step 1 On the shelf graphic, double-click the STM-16, STM-64, or ASAP card that you want to provision. The
card view appears.
Step 2 As needed, complete the following:
a. Click Line, Section, Path, or Physical to provision the line, section, path, and physical options in
Table 18-7 for each STM-N port.
b. Change the selection to Near End/Far End, 15 Min/1Day as necessary.
c. Click Refresh to view or modify the thresholds for each selection.
Note Far End section thresholds are not available for the STM-64 card.
Table 18-7 SDH Threshold Options (Line, Section, and Path)
Heading Description Options
Port Port number 1–16 for an STM-16 card, 1–4 for an STM-64
card, 1-1-1 to 4-4-1 for an ASAP port number
CV Coding violations Numeric. Can be set for 15-minute or one-day
intervals for Line, Section, or Path (Near and
Far End). Select the bullet and click Refresh.
ES Errored seconds Numeric. Can be set for 15-minute or one-day
intervals for Line, Section, or Path (Near and
Far End). Select the bullet and click Refresh.
Numeric. The defaults (15 min/1 day) are:
SES Severely errored seconds Numeric. Can be set for 15-minute or one-day
intervals for Line, Section, or Path (Near and
Far End). Select the bullet and click Refresh.
SEFS Severely errored framing seconds Numeric. Can be set for 15-minute or one-day
intervals for Section (Near and Far End). Select
the bullet and click Refresh.
FC Failure count Numeric. Can be set for 15-minute or one-day
intervals for Line or Path (Near and Far End).
Select the bullet and click Refresh.
UAS Unavailable seconds Numeric. Can be set for 15-minute or one-day
intervals for Line or Path (Near and Far End).
Select the bullet and click Refresh.
PSC Protection Switching Count (Line) Numeric. Can be set for 15-minute or one-day
intervals for Line (Near End). Select the bullet
and click Refresh.
PSD Protection Switch Duration (Line) Numeric. Can be set for 15-minute or one-day
intervals for Line (Near End). Select the bullet
and click Refresh.
PSC-W Protection Switching Count
(Working Line)
Numeric. Can be set for 15-minute or one-day
intervals for Line (Near End). Select the bullet
and click Refresh.