user manual
4-8
Cisco Physical Access Gateway User Guide
OL-20932-02
Chapter 4 Connecting a Cisco Input Module
Installing the Cisco Input Module
b. (Optional, for supervised input connections only). Install two End-Of-Line (EOL) 1K termination
resistors in each supervised input interface (one terminator in each connector). Figure 4-8 shows the
terminator installation for a Normally Closed (NC) and Normally Open (NO) input connection.
Figure 4-8 Input Connections: Cisco Physical Access Gateway and Reader Module
c.
Connect the wires from the input devices.
Note Each of the input connections can be configured as supervised or unsupervised. The tamper
(TM) and power fail (PF) inputs can be configured as additional unsupervised ports. A
supervised input supports four states: normal, alarm, open and short. An unsupervised input
indicates only normal or alarm.
Step 5 See the Cisco Physical Access Manager User Guide for information to configure the module ports.
NC
NO
1K,, 1%
1K,, 1%
1K,, 1%
1K,, 1%
187838