user manual
Table Of Contents
- Cisco ONS 15454 SDH Reference Manual
- Contents
- About this Guide
- Shelf and FMEC Hardware
- Common Control Cards
- Electrical Cards
- Optical Cards
- Ethernet Cards
- Storage Access Networking Cards
- Card Protection
- Cisco Transport Controller Operation
- Security and Timing
- Circuits and Tunnels
- SDH Topologies and Upgrades
- CTC Network Connectivity
- Alarm Monitoring and Management
- Ethernet Operation
- Hardware Specifications
- A.1 Shelf Specifications
- A.2 SFP Specifications
- A.3 General Card Specifications
- A.4 Common Control Card Specifications
- A.5 Electrical Card and FMEC Specifications
- A.5.1 E1-N-14 Card Specifications
- A.5.2 E1-42 Card Specifications
- A.5.3 E3-12 Card Specifications
- A.5.4 DS3i-N-12 Card Specifications
- A.5.5 STM1E-12 Card Specifications
- A.5.6 BLANK Card
- A.5.7 FMEC-E1 Specifications
- A.5.8 FMEC-DS1/E1 Card Specifications
- A.5.9 FMEC E1-120NP Card Specifications
- A.5.10 FMEC E1-120PROA Card Specifications
- A.5.11 FMEC E1-120PROB Card Specifications
- A.5.12 E1-75/120 Impedance Conversion Panel Specifications
- A.5.13 FMEC-E3/DS3 Card Specifications
- A.5.14 FMEC STM1E 1:1 Card Specifications
- A.5.15 FMEC-BLANK Card Specifications
- A.5.16 MIC-A/P Card Specifications
- A.5.17 MIC-C/T/P Card Specifications
- A.6 Optical Card Specifications
- A.6.1 OC3 IR 4/STM1 SH 1310 Card Specifications
- A.6.2 OC3 IR/STM1 SH 1310-8 Card Specifications
- A.6.3 OC12 IR/STM4 SH 1310 Card Specifications
- A.6.4 OC12 LR/STM4 LH 1310 Card Specifications
- A.6.5 OC12 LR/STM4 LH 1550 Card Specifications
- A.6.6 OC12 IR/STM4 SH 1310-4 Card Specifications
- A.6.7 OC48 IR/STM16 SH AS 1310 Card Specifications
- A.6.8 OC48 LR/STM16 LH AS 1550 Card Specifications
- A.6.9 OC48 ELR/STM16 EH 100 GHz Card Specifications
- A.6.10 OC192 SR/STM64 IO 1310 Card Specifications
- A.6.11 OC192 IR/STM64 SH 1550 Card Specifications
- A.6.12 OC192 LR/STM64 LH 1550 Card Specifications
- A.6.13 OC192 LR/STM64 LH ITU 15xx.xx Card Specifications
- A.7 Ethernet Card Specifications
- A.8 Storage Access Networking Card Specifications
- Administrative and Service States
- Network Element Defaults
- Index

1-11
Cisco ONS 15454 SDH Reference Manual, R5.0
April 2008
Chapter 1 Shelf and FMEC Hardware
1.7 Cable Routing and Management
All E-1 interfaces that are listed in Table 1-2 on page 1-8 with DB-37 or with Molex 96-pin LFH
connectors must be connected using a 120-ohm twisted-pair balanced cable. For the interfaces that use
Molex 96-pin LFH connectors Cisco offers ready-made cables.
1.7 Cable Routing and Management
The ONS 15454 SDH cable management facilities include the following:
• A cable-routing channel (behind the fold-down door) that runs the width of the shelf assembly,
Figure 1-7
• Plastic horseshoe-shaped fiber guides at each side opening of the cable-routing channel that ensure
the proper bend radius is maintained in the fibers, Figure 1-8 on page 1-12
Note You can remove the fiber guide if necessary to create a larger opening (if you need to route
CAT-5 Ethernet cables out the side, for example). To remove the fiber guide, take out the
three screws that anchor it to the side of the shelf assembly.
• A fold-down door that provides access to the cable-management tray
• Reversible jumper routing fins that enable you to route cables out either side by positioning the fins
as desired
Note To remove the jumper slack storage reels, take out the screw in the center of each reel.
• Optional fiber management tray (recommended for DWDM nodes)
Figure 1-7 shows the cable management facilities that you can access through the fold-down front door,
including the cable-routing channel and the jumper routing fins.
Figure 1-7 Managing Cables on the Front Panel
FAN FAIL
CRIT
MAJ
MIN
34238
Reversible jumper
routing fins
Fold down
front door