user manual
Table Of Contents
- Cisco ONS 15454 SDH Reference Manual
- Contents
- About this Guide
- Shelf and FMEC Hardware
- Common Control Cards
- Electrical Cards
- Optical Cards
- Ethernet Cards
- Storage Access Networking Cards
- Card Protection
- Cisco Transport Controller Operation
- Security and Timing
- Circuits and Tunnels
- SDH Topologies and Upgrades
- CTC Network Connectivity
- Alarm Monitoring and Management
- Ethernet Operation
- Hardware Specifications
- A.1 Shelf Specifications
- A.2 SFP Specifications
- A.3 General Card Specifications
- A.4 Common Control Card Specifications
- A.5 Electrical Card and FMEC Specifications
- A.5.1 E1-N-14 Card Specifications
- A.5.2 E1-42 Card Specifications
- A.5.3 E3-12 Card Specifications
- A.5.4 DS3i-N-12 Card Specifications
- A.5.5 STM1E-12 Card Specifications
- A.5.6 BLANK Card
- A.5.7 FMEC-E1 Specifications
- A.5.8 FMEC-DS1/E1 Card Specifications
- A.5.9 FMEC E1-120NP Card Specifications
- A.5.10 FMEC E1-120PROA Card Specifications
- A.5.11 FMEC E1-120PROB Card Specifications
- A.5.12 E1-75/120 Impedance Conversion Panel Specifications
- A.5.13 FMEC-E3/DS3 Card Specifications
- A.5.14 FMEC STM1E 1:1 Card Specifications
- A.5.15 FMEC-BLANK Card Specifications
- A.5.16 MIC-A/P Card Specifications
- A.5.17 MIC-C/T/P Card Specifications
- A.6 Optical Card Specifications
- A.6.1 OC3 IR 4/STM1 SH 1310 Card Specifications
- A.6.2 OC3 IR/STM1 SH 1310-8 Card Specifications
- A.6.3 OC12 IR/STM4 SH 1310 Card Specifications
- A.6.4 OC12 LR/STM4 LH 1310 Card Specifications
- A.6.5 OC12 LR/STM4 LH 1550 Card Specifications
- A.6.6 OC12 IR/STM4 SH 1310-4 Card Specifications
- A.6.7 OC48 IR/STM16 SH AS 1310 Card Specifications
- A.6.8 OC48 LR/STM16 LH AS 1550 Card Specifications
- A.6.9 OC48 ELR/STM16 EH 100 GHz Card Specifications
- A.6.10 OC192 SR/STM64 IO 1310 Card Specifications
- A.6.11 OC192 IR/STM64 SH 1550 Card Specifications
- A.6.12 OC192 LR/STM64 LH 1550 Card Specifications
- A.6.13 OC192 LR/STM64 LH ITU 15xx.xx Card Specifications
- A.7 Ethernet Card Specifications
- A.8 Storage Access Networking Card Specifications
- Administrative and Service States
- Network Element Defaults
- Index

REVIEW DRAFT—CISCO CONFIDENTIAL
14-7
Cisco ONS 15454 SDH Reference Manual, R5.0
April 2008
Chapter 14 Ethernet Operation
14.2.1 Two-Port Bidirectional Transponder
In transponder mode, the G-Series Ethernet traffic never comes into contact with the cross-connect card
or the SDH network, but stays internal to the G-Series card and is routed back to a GBIC on that card
(Figure 14-6).
Figure 14-6 G-Series Card in Transponder Mode (Two-Port Bidirectional)
A G-Series card can either be configured for transponding mode or as the SDH default. Once any port
is provisioned in transponding mode, the card is in transponding mode and no SDH circuits can be
configured until every port on the card goes back to SDH mode. Refer to the Cisco ONS 15454 SDH
Procedure Guide for instructions on how to provision G-Series ports for transponder mode.
All SDH circuits must be deleted before a G-Series card can be configured in transponding mode. An
ONS 15454 SDH can host the card in any of the twelve traffic slots on the ONS 15454 SDH and supports
a maximum of 24 bidirectional or 48 unidirectional lambdas.
A G-Series card configured as a transponder can be in one of three modes:
• Two-port bidirectional transponding mode
• One-port bidirectional transponding mode
• Two-port unidirectional transponding mode
14.2.1 Two-Port Bidirectional Transponder
Two-port bidirectional transponder mode maps the transmitted and received Ethernet frames of one
G-Series card port into the transmit and receive of another port (Figure 14-6). Transponder bidirectional
port mapping can be between any two ports on the same card.
90911
G-Series Card
Tx Port
Rx Port
ONS Node
Cross-Connect
Card
Optical Card
Tx Port
Rx Port
GBIC Standard SX, LX, ZX
GBIC CWDM or DWDM
Ethernet TDM
xWDM Lambda1
xWDM Lambda 2