user manual
Table Of Contents
- Cisco ONS 15454 SDH Reference Manual
- Contents
- About this Guide
- Shelf and FMEC Hardware
- Common Control Cards
- Electrical Cards
- Optical Cards
- Ethernet Cards
- Storage Access Networking Cards
- Card Protection
- Cisco Transport Controller Operation
- Security and Timing
- Circuits and Tunnels
- SDH Topologies and Upgrades
- CTC Network Connectivity
- Alarm Monitoring and Management
- Ethernet Operation
- Hardware Specifications
- A.1 Shelf Specifications
- A.2 SFP Specifications
- A.3 General Card Specifications
- A.4 Common Control Card Specifications
- A.5 Electrical Card and FMEC Specifications
- A.5.1 E1-N-14 Card Specifications
- A.5.2 E1-42 Card Specifications
- A.5.3 E3-12 Card Specifications
- A.5.4 DS3i-N-12 Card Specifications
- A.5.5 STM1E-12 Card Specifications
- A.5.6 BLANK Card
- A.5.7 FMEC-E1 Specifications
- A.5.8 FMEC-DS1/E1 Card Specifications
- A.5.9 FMEC E1-120NP Card Specifications
- A.5.10 FMEC E1-120PROA Card Specifications
- A.5.11 FMEC E1-120PROB Card Specifications
- A.5.12 E1-75/120 Impedance Conversion Panel Specifications
- A.5.13 FMEC-E3/DS3 Card Specifications
- A.5.14 FMEC STM1E 1:1 Card Specifications
- A.5.15 FMEC-BLANK Card Specifications
- A.5.16 MIC-A/P Card Specifications
- A.5.17 MIC-C/T/P Card Specifications
- A.6 Optical Card Specifications
- A.6.1 OC3 IR 4/STM1 SH 1310 Card Specifications
- A.6.2 OC3 IR/STM1 SH 1310-8 Card Specifications
- A.6.3 OC12 IR/STM4 SH 1310 Card Specifications
- A.6.4 OC12 LR/STM4 LH 1310 Card Specifications
- A.6.5 OC12 LR/STM4 LH 1550 Card Specifications
- A.6.6 OC12 IR/STM4 SH 1310-4 Card Specifications
- A.6.7 OC48 IR/STM16 SH AS 1310 Card Specifications
- A.6.8 OC48 LR/STM16 LH AS 1550 Card Specifications
- A.6.9 OC48 ELR/STM16 EH 100 GHz Card Specifications
- A.6.10 OC192 SR/STM64 IO 1310 Card Specifications
- A.6.11 OC192 IR/STM64 SH 1550 Card Specifications
- A.6.12 OC192 LR/STM64 LH 1550 Card Specifications
- A.6.13 OC192 LR/STM64 LH ITU 15xx.xx Card Specifications
- A.7 Ethernet Card Specifications
- A.8 Storage Access Networking Card Specifications
- Administrative and Service States
- Network Element Defaults
- Index

8-7
Cisco ONS 15454 SDH Reference Manual, R5.0
April 2008
Chapter 8 Cisco Transport Controller Operation
8.5.1 Node View
Figure 8-3 Node View (Default Login View)
8.5.1 Node View
Node view, shown in Figure 8-3, is the first view open after you log into an ONS 15454 SDH. The login
node is the first node shown, and it is the “home view” for the session. Node view allows you to view
and manage one ONS 15454 SDH node. The status area shows the node name; IP address; session boot
date and time; number of Critical (CR), Major (MJ), and Minor (MN) alarms; the name of the current
logged-in user; and the security level of the user; software version; and the network element default
setup.
8.5.1.1 CTC Card Colors
The graphic area of the CTC window depicts the ONS 15454 SDH shelf assembly. The colors of the
cards in the graphic reflect the real-time status of the physical card and slot (Table 8-4).
Menu
102028
Tool bar
Status area
Node view Upper FMEC shelf
Tabs
Status bar
Subtabs
Graphic area
Table 8-4 Node View Card Colors
Card Color Status
Gray Slot is not provisioned; no card is installed.
Violet Slot is provisioned; no card is installed.
White Slot is provisioned; a functioning card is installed.
Yellow Slot is provisioned; a Minor alarm condition exists.