user manual
Table Of Contents
- Cisco ONS 15454 SDH Reference Manual
- Contents
- About this Guide
- Shelf and FMEC Hardware
- Common Control Cards
- Electrical Cards
- Optical Cards
- Ethernet Cards
- Storage Access Networking Cards
- Card Protection
- Cisco Transport Controller Operation
- Security and Timing
- Circuits and Tunnels
- SDH Topologies and Upgrades
- CTC Network Connectivity
- Alarm Monitoring and Management
- Ethernet Operation
- Hardware Specifications
- A.1 Shelf Specifications
- A.2 SFP Specifications
- A.3 General Card Specifications
- A.4 Common Control Card Specifications
- A.5 Electrical Card and FMEC Specifications
- A.5.1 E1-N-14 Card Specifications
- A.5.2 E1-42 Card Specifications
- A.5.3 E3-12 Card Specifications
- A.5.4 DS3i-N-12 Card Specifications
- A.5.5 STM1E-12 Card Specifications
- A.5.6 BLANK Card
- A.5.7 FMEC-E1 Specifications
- A.5.8 FMEC-DS1/E1 Card Specifications
- A.5.9 FMEC E1-120NP Card Specifications
- A.5.10 FMEC E1-120PROA Card Specifications
- A.5.11 FMEC E1-120PROB Card Specifications
- A.5.12 E1-75/120 Impedance Conversion Panel Specifications
- A.5.13 FMEC-E3/DS3 Card Specifications
- A.5.14 FMEC STM1E 1:1 Card Specifications
- A.5.15 FMEC-BLANK Card Specifications
- A.5.16 MIC-A/P Card Specifications
- A.5.17 MIC-C/T/P Card Specifications
- A.6 Optical Card Specifications
- A.6.1 OC3 IR 4/STM1 SH 1310 Card Specifications
- A.6.2 OC3 IR/STM1 SH 1310-8 Card Specifications
- A.6.3 OC12 IR/STM4 SH 1310 Card Specifications
- A.6.4 OC12 LR/STM4 LH 1310 Card Specifications
- A.6.5 OC12 LR/STM4 LH 1550 Card Specifications
- A.6.6 OC12 IR/STM4 SH 1310-4 Card Specifications
- A.6.7 OC48 IR/STM16 SH AS 1310 Card Specifications
- A.6.8 OC48 LR/STM16 LH AS 1550 Card Specifications
- A.6.9 OC48 ELR/STM16 EH 100 GHz Card Specifications
- A.6.10 OC192 SR/STM64 IO 1310 Card Specifications
- A.6.11 OC192 IR/STM64 SH 1550 Card Specifications
- A.6.12 OC192 LR/STM64 LH 1550 Card Specifications
- A.6.13 OC192 LR/STM64 LH ITU 15xx.xx Card Specifications
- A.7 Ethernet Card Specifications
- A.8 Storage Access Networking Card Specifications
- Administrative and Service States
- Network Element Defaults
- Index

8-4
Cisco ONS 15454 SDH Reference Manual, R5.0
April 2008
Chapter 8 Cisco Transport Controller Operation
8.3 PC and UNIX Workstation Requirements
Note To avoid network performance issues, Cisco recommends managing a maximum of 50 nodes
concurrently with CTC. The 50 nodes can be on a single DCC or split across multiple DCCs. Cisco does
not recommend running multiple CTC sessions when managing two or more large networks.
To manage more than 50 nodes, Cisco recommends using Cisco Transport Manager (CTM). If you do
use CTC to manage more than 50 nodes, you can improve performance by adjusting the heap size; see
the “General Troubleshooting” chapter of the Cisco ONS 15454 SDH Troubleshooting Guide. You can
also create login node groups; see the “Connect the PC and Log Into the GUI” chapter of the
Cisco ONS 15454 SDH Procedure Guide.
Table 8-2 lists the requirements for PCs and UNIX workstations. In addition to the JRE, the Java plug-in
and modified java.policy file are also included on the ONS 15454 SDH software CD and the ONS 15454
SDH documentation CD.
Table 8-1 JRE Compatibility
ONS Software Release JRE 1.2.2 Compatible JRE 1.3 Compatible JRE 1.4 Compatible
ONS 15454 SDH Release 3.3 Yes Yes No
ONS 15454 SDH Release 3.4 No Yes No
ONS 15454 SDH Release 4.0
1
1. Software releases 4.0 and later notify you if an older version of the JRE is running on your PC or UNIX workstation.
No Yes No
ONS 15454 SDH Release 4.1 No Yes No
ONS 15454 SDH Release 4.5 No Yes No
ONS 15454 SDH Release 4.6 No Yes Yes
ONS 15454 SDH Release 4.7 No Yes Yes
ONS 15454 SDH Release 5.0 No No Yes
Table 8-2 CTC Computer Requirements
Area Requirements Notes
Processor
(PC only)
Pentium 4 processor or equivalent A faster CPU is recommended if your
workstation runs multiple
applications or if CTC manages a
network with a large number of nodes
and circuits.
RAM 512 MB or more A minimum of 1 GB is recommended
if your workstation runs multiple
applications or if CTC manages a
network with a large number of nodes
and circuits.
Hard drive 20 GB hard drive with 50 MB of space
available
CTC application files are
downloaded from the TCC2/TCC2P
to your computer’s Temp directory.
These files occupy 5 to 10 MB of
hard drive space.