user manual
Table Of Contents
- Cisco ONS 15454 SDH Reference Manual
- Contents
- About this Guide
- Shelf and FMEC Hardware
- Common Control Cards
- Electrical Cards
- Optical Cards
- Ethernet Cards
- Storage Access Networking Cards
- Card Protection
- Cisco Transport Controller Operation
- Security and Timing
- Circuits and Tunnels
- SDH Topologies and Upgrades
- CTC Network Connectivity
- Alarm Monitoring and Management
- Ethernet Operation
- Hardware Specifications
- A.1 Shelf Specifications
- A.2 SFP Specifications
- A.3 General Card Specifications
- A.4 Common Control Card Specifications
- A.5 Electrical Card and FMEC Specifications
- A.5.1 E1-N-14 Card Specifications
- A.5.2 E1-42 Card Specifications
- A.5.3 E3-12 Card Specifications
- A.5.4 DS3i-N-12 Card Specifications
- A.5.5 STM1E-12 Card Specifications
- A.5.6 BLANK Card
- A.5.7 FMEC-E1 Specifications
- A.5.8 FMEC-DS1/E1 Card Specifications
- A.5.9 FMEC E1-120NP Card Specifications
- A.5.10 FMEC E1-120PROA Card Specifications
- A.5.11 FMEC E1-120PROB Card Specifications
- A.5.12 E1-75/120 Impedance Conversion Panel Specifications
- A.5.13 FMEC-E3/DS3 Card Specifications
- A.5.14 FMEC STM1E 1:1 Card Specifications
- A.5.15 FMEC-BLANK Card Specifications
- A.5.16 MIC-A/P Card Specifications
- A.5.17 MIC-C/T/P Card Specifications
- A.6 Optical Card Specifications
- A.6.1 OC3 IR 4/STM1 SH 1310 Card Specifications
- A.6.2 OC3 IR/STM1 SH 1310-8 Card Specifications
- A.6.3 OC12 IR/STM4 SH 1310 Card Specifications
- A.6.4 OC12 LR/STM4 LH 1310 Card Specifications
- A.6.5 OC12 LR/STM4 LH 1550 Card Specifications
- A.6.6 OC12 IR/STM4 SH 1310-4 Card Specifications
- A.6.7 OC48 IR/STM16 SH AS 1310 Card Specifications
- A.6.8 OC48 LR/STM16 LH AS 1550 Card Specifications
- A.6.9 OC48 ELR/STM16 EH 100 GHz Card Specifications
- A.6.10 OC192 SR/STM64 IO 1310 Card Specifications
- A.6.11 OC192 IR/STM64 SH 1550 Card Specifications
- A.6.12 OC192 LR/STM64 LH 1550 Card Specifications
- A.6.13 OC192 LR/STM64 LH ITU 15xx.xx Card Specifications
- A.7 Ethernet Card Specifications
- A.8 Storage Access Networking Card Specifications
- Administrative and Service States
- Network Element Defaults
- Index

3-31
Cisco ONS 15454 SDH Reference Manual, R5.0
April 2008
Chapter 3 Electrical Cards
3.17.1 MIC-A/P Connector Pinouts
Note For proper system operation, both the MIC-A/P and the MIC-C/T/P FMECs must be installed in the
ONS 15454 SDH shelf.
Note The MIC-A/P card controls whether FMEC cards on its side of the shelf appear in the CTC graphical
user interface (GUI). For example, if the MIC-A/P is removed from the shelf, FMECS to the left of the
card may disappear in CTC. This is normal behavior because when the MIC-A/P card is removed,
communication can no longer be established with the disappeared FMECS. For more information, refer
to the IMPROPROMVL entry in the “Alarm Troubleshooting” chapter of the Cisco ONS 15454 SDH
Troubleshooting Guide.
3.17.1 MIC-A/P Connector Pinouts
Table 3-16 shows the alarm interface pinouts on the MIC-A/P DB-62 connector.
Table 3-16 Alarm Interface Pinouts on the MIC-A/P DB-62 Connector
Pin No. Signal Name Signal Description Color
1 ALMCUTOFF N Alarm cutoff, normally open ACO pair White/blue
2 ALMCUTOFF P Alarm cutoff, normally open ACO pair Blue/white
3 ALMINP0 N Alarm input pair 1, reports closure on connected wires White/orange
4 ALMINP0 P Alarm input pair 1, reports closure on connected wires Orange/white
5 ALMINP1 N Alarm input pair 2, reports closure on connected wires White/green
6 ALMINP1 P Alarm input pair 2, reports closure on connected wires Green/white
7 ALMINP2 N Alarm input pair 3, reports closure on connected wires White/brown
8 ALMINP2 P Alarm input pair 3, reports closure on connected wires Brown/white
9 ALMINP3 N Alarm input pair 4, reports closure on connected wires White/gray
10 ALMINP3 P Alarm input pair 4, reports closure on connected wires Gray/white
11 EXALM0 N External customer alarm 1 Red/blue
12 EXALM0 P External customer alarm 1 Blue/red
13 GND Frame ground —
14 EXALM1 N External customer alarm 2 Red/orange
15 EXALM1 P External customer alarm 2 Orange/red
16 EXALM2 N External customer alarm 3 Red/green
17 EXALM2 P External customer alarm 3 Green/red
18 EXALM3 N External customer alarm 4 Red/brown
19 EXALM3 P External customer alarm 4 Brown/red
20 EXALM4 N External customer alarm 5 Red/gray
21 EXALM4 P External customer alarm 5 Gray/red
22 EXALM5 N External customer alarm 6 Black/blue