Network Device Installation Guide

Send documentation comments to mdsfeedback-doc@cisco.com.
D-1
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
APPENDIX
D
Technical Specifications
This appendix provides technical specifications and includes the following sections:
Switch Specifications, page D-1
Module Specifications, page D-4
Power Specifications for the Cisco MDS 9513 Director, page D-6
Power Specifications for the Cisco MDS 9509 Director, page D-9
Power Specifications for the Cisco MDS 9506 Director, page D-14
X2 Transceiver Specifications, page D-19
SFP and SFP+ Transceiver Specifications, page D-22
Note Specifications for cables and connectors are provided in Appendix E, “Cable and Port Specifications.
Switch Specifications
The Cisco MDS 9500 Series supports hot-swappable fan modules that provide 85 cfm (cubic feet per
minute) of airflow per slot with 410 W of power dissipation per slot.
Table D-1 lists the environmental specifications for the Cisco MDS 9500 Series.
Ta b l e D-1 Environmental Specifications for the Cisco MDS 9500 Series
Description Specification
Temperature, certified for operation 32 to 104°F (0 to 40°C)
Temperature, designed and tested for operation 32 to 130°F (0 to 55°C)
Temperature, ambient nonoperating and storage -40 to 158°F (-40 to 70°C)
Humidity (RH), ambient (noncondensing)
operating
10 to 90%
Humidity (RH), ambient (noncondensing)
nonoperating and storage
5 to 95%
Altitude, certified for operation 0 to 6500 ft (0 to 2000 m)
Altitude, designed and tested for operation -200 to 10000 ft (-60 to 3000 m)
Noise levels 70 dB