Network Device Installation Guide

Send documentation comments to mdsfeedback-doc@cisco.com.
A-6
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules
Migration Procedures for the MDS 9513 Director
switch# show module
Mod Ports Module-Type Model Status
--- ----- -------------------------------- ------------------ ------------
7 0 Supervisor/Fabric-2 DS-X9530-SF2-K9 ha-standby
8 0 Supervisor/Fabric-2 DS-X9530-SF2-K9 active *
switch# out-of-service xbar 1
Step 5 Enter the show module xbar command to verify that the standby supervisor module is powered down.
Step 6 Attach a ESD wrist strap according to the instructions in the section “Preventing Electrostatic Discharge
Damage” section on page 2-19.
Step 7 Confirm that the LED light is red, which indicates that the module is powered off, and then loosen the
two captive screws on the module being removed.
Step 8 Remove the module from the chassis as follows:
a. Place your thumbs on the top and bottom ejector levers and simultaneously rotate the levers outward
to unseat the module from the midplane connector. (See
Figure A-1)
b. Hold the front edge of the module and slide the module partially out of the slot. Do not touch the
module circuitry.