Regulatory Compliance and Safety Information for the Catalyst 8500 and LightStream 1010 Series Read this document before installing or servicing the following Catalyst 8500 and LightStream 1010 series switches: • Catalyst 8540 MSR • Catalyst 8510 MSR • Catalyst 8540 CSR • Catalyst 8510 CSR • LightStream 1010 ATM switch Note Only trained and qualified service personnel (as defined in IEC 60950 and AS/NZS 3260) should install, replace, or service the equipment.
Site Preparation • Related Documentation, page 26 • Obtaining Documentation, page 27 • Obtaining Technical Assistance, page 28 • Obtaining Additional Publications and Information, page 30 Site Preparation This section describes the site requirements for installing the Catalyst 8500 MSR, Catalyst 8500 CSR, and LightSteam 1010 series switches. To ensure normal system operation, plan your site configuration and prepare your site before installation.
Site Preparation Rack-Mounting the System A rack-mount kit and cable guides come with the system. The kit is not suitable for racks with obstructions (such as a power strip) that could impair access to system components. Allow sufficient clearance around the rack for system maintenance. Ensuring Proper Airflow Follow these guidelines to ensure proper airflow: • Install the system in an open rack whenever possible.
Site Preparation Figure 1 Catalyst 8540 Chassis Standard Equipment Rack Dimensions 17.25 " (45.09 cm) 79100 19.25 " (48.
Site Preparation Catalyst 8510 and LightStream 1010 Chassis Standard Equipment Rack Dimensions N FA 2 PS 1 PS T SE TX RE OT 2 SL RX K OT LIN E X 1 OL AU SL NS CO et IA En MC PC T EC EJ 19.25 " (48.09 cm) 79099 Figure 2 17.25 " (45.09 cm) • Ensure that the weight of the chassis does not make the rack unstable. Secure telco racks with ceiling brackets if the rack is populated with heavy equipment. • Bolt the rack to the floor for stability.
Site Preparation Figure 3 Safely Lifting the System <40 lb (<18 kg) 40 to 70 lb (18 to 32 kg) 70 to 121 lb (32 to 55 kg) >121 lb (>55 kg) 18986 Figure 3 shows the number of people needed to lift the system by weight. Power Considerations AC and DC power supplies, and an optional redundant (second) power supply, are available for most systems. Be careful when connecting systems to the supply circuit so that wiring is not overloaded.
Site Preparation Using Redundant Power If your system includes an optional redundant (second) power supply, connect each of the two power supplies to different input power sources. Failure to do so makes the system susceptible to total power failure in the event that one of the power supplies fails. Preventing ESD Electrostatic discharge (ESD) damage occurs when electronic cards or components are mishandled and can result in complete or intermittent failures.
Site Preparation Disconnecting Power Follow these guidelines when disconnecting power: • Locate the emergency power-off switch for the room before working with the system. • Turn off the power and disconnect the power from the circuit when working with components that are not hot-swappable or when working near the system backplane or midplane. If the system does not have an on/off switch, unplug the power cord.
Regulatory Standards Compliance • Direct the flow of cooling air through the chassis • Protect the backplane from dust Disposing of the System Dispose of the system and its components (including batteries) as specified by all national laws and regulations. Regulatory Standards Compliance This section includes the regulatory compliance, safety, and EMC standards. It also lists the warnings applicable to different countries. Table 1 lists the regulatory standards compliance specifications.
Regulatory Standards Compliance Table 2 lists the NEBS and ETSI specifications that the Catalyst 8500 MSR, Catalyst 8500 CSR, and LightSteam 1010 series switches are designed to meet. Table 2 NEBS and ETSI Specifications Specification NEBS 1 Description GR-63-Core NEBS Level 3 Requirements GR-1089-Core NEBS Level 3 Requirements ETSI 2 ETS 300 019 Storage Class 1.1 ETS 300 019 Transportation Class 2.3 ETS 300 019 Stationary Use Class 3.1 1. NEBS = Network Equipment Building Systems 2.
Regulatory Standards Compliance Table 3 USOC Jacks for CES Port Adapters (continued) Model No. Facility Interface Code Service Order Code Jack Type WAI-T1C-4RJ48 04DU9-BN 6.0N — WAI-T1C-4RJ48 04DU9-DN 6.0N — WAI-T1C-4RJ48 04DU9-1KN 6.0N — WAI-T1C-4RJ48 04DU9-1SN 6.0N — WAI-T1C-4RJ48 04DU9-1ZN 6.0N — CS-03 Certification The T1 IMA interface module is CS-03 certified. See Table 4 for CS-03 approval details for the equipment.
Regulatory Standards Compliance JATE The T1 IMA interface module meets the requirements of the Japan Approvals Institute for Telecommunications Equipment (JATE). Table 5 provides the JATE approval details for modules.
Regulatory Standards Compliance Nederlands: Norsk: Português: Suomalainen: Deze apparatuur voldoet aan de belangrijkste eisen en andere voorzieningen van richtlijnen 73/23/EEC en 89/336/EEC zoals gewijzigd door richtlijn 93/68/EEC. Dette utstyret samsvarer med de vesentligste kravene og andre regler i direktivene 73/23/EEC og 89/336/EEC samt i tilleggsdirektiv 93/68/EEC.
Regulatory Standards Compliance Canada Class A Warning Warning This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numèrique de la classe A est conforme á la norme NMB-003 du Canada. CISPR 22 Class A Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Regulatory Standards Compliance Class A Notice for Hungary Warning This equipment is a class A product and should be used and installed properly according to the Hungarian EMC Class A requirements (MSZEN55022). Class A equipment is designed for typical commercial establishments for which special conditions of installation and protection distance are used. Korean Class A Warning Warning This is a Class A Device and is registered for EMC requirements for industrial use.
Translated Safety Warnings Translated Safety Warnings This section includes translations in multiple languages of the warnings that may appear in the Catalyst 8500 MSR, Catalyst 8500 CSR, and LightSteam 1010 series switch product documents. Warning Definition Warning IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger. You are in a situation that could cause bodily injury.
Translated Safety Warnings Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut.
Translated Safety Warnings Varning! VIKTIGA SÄKERHETSANVISNINGAR Denna varningssignal signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanliga förfaranden för att förebygga olyckor. Använd det nummer som finns i slutet av varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medföljer denna anordning.
Translated Safety Warnings Backplane Voltage Warning Waarschuwing Varoitus Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. Er is gevaarlijke spanning of energie aanwezig op de achterplaat wanneer het systeem bediend wordt. Wees voorzichtig bij het onderhoud. Kun laite on toiminnassa, taustalevyyn muodostuu vaarallista jännitettä. Ole varovainen huoltaessasi laitetta.
Translated Safety Warnings Ground Conductor Warning This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Waarschuwing Deze apparatuur dient geaard te zijn.
Translated Safety Warnings Restricted Area Warning Warning This unit is intended for installation in restricted access areas. A restricted access area is where access can only be gained by service personnel through the use of a special tool, lock and key, or other means of security, and is controlled by the authority responsible for the location. Waarschuwing Dit toestel is bedoeld voor installatie op plaatsen met beperkte toegang.
Translated Safety Warnings Avvertenza Advarsel Aviso Questa unità deve essere installata in un'area ad accesso limitato. Un'area ad accesso limitato è un'area accessibile solo a personale di assistenza tramite un'attrezzo speciale, lucchetto, o altri dispositivi di sicurezza, ed è controllata dall'autorità responsabile della zona. Denne enheten er laget for installasjon i områder med begrenset adgang.
Translated Safety Warnings Varning Denna utrustning ska endast installeras och bytas ut av utbildad och kvalificerad personal. Warning Definition Warning This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents.
Translated Safety Warnings Warnung Avvertenza Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu einer Körperverletzung führen könnte. Bevor Sie mit der Arbeit an irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen Stromkreisen verbundenen Gefahren und der Standardpraktiken zur Vermeidung von Unfällen bewußt.
Translated Safety Warnings Disconnect Device Warning Warning Waarschuwing Varoitus A readily accessible two-poled disconnect device must be incorporated in the fixed wiring. Er moet een gemakkelijk toegankelijke, tweepolige stroomverbreker opgenomen zijn in de vaste bedrading. Kiinteään johdotukseen on liitettävä kaksinapainen kytkinlaite, johon on helppo päästä käsiksi. Attention Un disjoncteur bipolaire facile d’accès doit être intégré dans le câblage fixe.
Related Documentation Warnung Avvertenza Advarsel Aviso Aus der Öffnung des optischen OC-3 Typ NI-2 Schnittstellenanschlusses kann unsichtbare Laserstrahlung austreten, wenn kein Kabel angeschlossen ist. Kontakt mit Laserstrahlung vermeiden und nicht in offene Öffnungen blicken.
Obtaining Documentation 1. You can order printed versions of documents with DOC numbers. Documents with OL numbers are available online only, but they can be printed from PDF.
Obtaining Technical Assistance Documentation CD-ROM Cisco documentation and additional literature are available in a Cisco Documentation CD-ROM package, which may have shipped with your product. The Documentation CD-ROM is updated regularly and may be more current than printed documentation. The CD-ROM package is available as a single unit or through an annual or quarterly subscription. Registered Cisco.
Obtaining Technical Assistance Cisco TAC Website The Cisco TAC website (http://www.cisco.com/tac) provides online documents and tools for troubleshooting and resolving technical issues with Cisco products and technologies. The Cisco TAC website is available 24 hours a day, 365 days a year. Accessing all the tools on the Cisco TAC website requires a Cisco.com user ID and password. If you have a valid service contract but do not have a login ID or password, register at this URL: http://tools.cisco.
Obtaining Additional Publications and Information Obtaining Additional Publications and Information Information about Cisco products, technologies, and network solutions is available from various online and printed sources. • The Cisco Product Catalog describes the networking products offered by Cisco Systems, as well as ordering and customer support services. Access the Cisco Product Catalog at this URL: http://www.cisco.com/en/US/products/products_catalog_links_launch.