User's Manual
22-14
Cisco IOS Software Configuration Guide for Cisco Aironet Access Points
OL-11350-01
Chapter 22 Wireless Device Troubleshooting
 Checking Power
• Cisco Aironet Power Injector LR2T—optional transportation version
–
12- to 40-VDC input power
–
Uses 12 to 40 VDC from a vehicle battery 
Checking Power
You can verify the availability of power to the access point/bridge by checking the power injector LED 
(see Figure 22-8):
• Power LED
–
Green color indicates input power is being supplied to the bridge.
–
Red color indicates an overcurrent or overvoltage error condition—disconnect input power from 
the power injector, check all coax cable connections for a possible short, wait approximately 1 
minute, and reconnect input power to the power injector. If the LED turns red again, contact 
technical support for assistance.
Note The power injector requires approximately 50 seconds to recover from an overcurrent or 
overvoltage condition.
Off indicates input power is not available—verify that the power module is connected to the power 
injector and that AC power is available or that 12- to 40-VDC input power is connected to the power 
injector.
Low Power Condition
Access points can be powered from the 48-VDC power module or from an in-line power source. The 
1130 and 1240 access points support the IEEE 802.3af power standard, Cisco Pre-Standard PoE 
protocol, and Cisco Intelligent Power Management for in-line power sources. 
For full operation, the 1130 and 1240 series access points require 12.95 W of power. The power module 
and Cisco Aironet power injectors are capable of supplying the required power for full operation, but 
some inline power sources are not capable of supplying 12.95 W. Also, some high-power inline power 
sources, might not be able to provide 12.95 W of power to all ports at the same time.
Note An 802.3af compliant switch (Cisco or non-Cisco) is capable of supplying sufficient power for full 
operation.
On power up, the 1130 and 1240 series access points are placed into low power mode (both radios are 
disabled), Cisco IOS software loads and runs, and power negotiation determines if sufficient power is 
available. If there is sufficient power then the radios are turned on; otherwise, the access point remains 
in low power mode with the radios disabled to prevent a possible over-current condition. In low power 
mode, the access point activates the Status LED low power error indication, displays a low power 