Network Router User Manual

5
Release Notes for CPE/CS3 Switch Software Release 2.2.0.3
78-10367-01
Caveats
Sn05174 0 Xyplex FTP failed
sometimes due
to Xyplex’s
problem.
Pending on Xyplex new
fix.
Same as
1.1.1.11
Sn05203 2 BERT Circuit will not
pass data if it is
created while
DS1s on both
ends of a local
circuit are
under BERT.
Workaround: Delete and
create the circuit again
after the BERT is
stopped.
Same as
1.1.1.11
Sn05554 1 FE Loopback If the user
manipulates
the far-end
DS1 loop
modes more
rapidly than
the 1.5 second
(the loop send
code duration
time), the
far-end
Larscom
CSU/DSU and
the Cisco
MGX 8240
DS1 port are
both in a loop
up mode. Once
this happens,
the loop down
command
issued from
Sentient NMS
is unable to
take Larscom
CSU/DSU out
of a loop.
Workaround:
1. On NMS go to the
port's Near End
Loopback. Invoke a
Near End
Loopback, then
drop the loop.
2. Go to the Far End
Loopback and
invoke the loop first
and then drop it.
Bug found in
1.1.2.10