Environmental Specifications
Table 10: Environmental Specifications for the Chassis
SpecificationDescription
50 to 95°F (10 to 35°C)
Temperature, operating within altitude: 0 to 10,000
feet (0 to 3,000 meters)
40 to 149°F (40 to 65°C)Temperature, non-operating within altitude: 0 to
40,000 feet (0 to 12,000 meters)
Operating: 10-90%, 28°C max. wet bulb
Nonoperating: 5-93%, 38°C max wet bulb
Humidity (RH), noncondensing
Operating 0 to 10000 feet (0 to 3000 meters) Above
10,000 feet, maximum temperature decreases by 1°C
per 1000 feet (~300 meters) above 10,000 feet
Nonoperating 40,000 ft (12,000 m)
Altitude
83 dBAat normal operating temperature.
Sound Pressure Level
Environmental Conditions and Power Requirement Specifications for Twinax
SFP+ Transceivers
Table 11: Environmental Conditions and Power Requirement for the SFP+ Transceiver
UnitMax.Min.SymbolParameter
°C85
40
TSStorage temperature
°C500TCCase temperature
V3.53.1VCCT,RModule supply voltage
Cisco UCS 5108 Server Chassis Installation Guide
OL-20035-05 71
Technical Specifications
Environmental Specifications