Bridge/Router Installation and Configuration Guide

Chapter 7 Maintaining the Router
Removing and Replacing the Optional 2-Level AC-Input Power Shelf
7-58
Cisco 12016, Cisco 12416, and Cisco 12816 Router Installation and Configuration Guide
OL-11495-01
TEMP (yellow)—Indicates that the power supply is in an overtemperature
condition, causing a shut-down to occur.
Note If the temp indicator is on, the fault indicator also goes on.
Verify that the power supply fan is operating properly.
Verify that the blower modules are operating properly.
If the blower modules are operating properly, replace the existing power
supply with a spare.
TEMP (flashing yellow—2500 W PEM only)—Indicates that a power supply
fan is locked or malfunctioning.
Note If the temp indicator is flashing, the fault indicator also goes on.
Check to see if the fan is operating. Remove anything that may be
obstructing the fan.
If the fan is not operating, replace the power supply.
ILIM (2000 W PEM only) (yellow)—Indicates the power supply is operating
in a current-limiting condition.
Each power cord should be connected to a dedicated AC power source.
Each AC power supply operating in the nominal range of 200 to 240 VAC
requires a minimum service of 20 A, North
America (or 13 A,
international).