Field-Programmable Gate Array Overview
6-6
Cisco 12016, Cisco 12416, and Cisco 12816 Router Installation and Configuration Guide
OL-11495-01
Step 2 Enter the diag slot-number update-fpga source {tftp | flash} source-path
command to update the flash memory.
Where:
• slot-number is the slot number of the line card you are upgrading.
• source-path is the path to the diagnostic image.
–
For flash memory cards, the source path is typically:
slot0:c12k-fdiagsbflc-mz.120-25.S or
slot1:c12k-fdiagsbflc-mz.120-25.S.
–
For TFTP boot servers, the source path is typically:
tftp://tftp_server_ip_address/my_directory/c12k-fdiagsbflc-mz.120-25
.S.
Caution Do not unplug the line card or terminate the field diagnostics session during this
test.
The following example shows the output of a line card with the update-fpga
option specified.
Router# diag 7 verbose source tftp
tftp://223.255.254.254/c12k-fdiagsbflc-mz.
120-25.S
update-fpga
Running DIAG config check
Fabric Download for Field Diags chosen: If timeout occurs, try 'mbus'
option.
Verbose mode: Test progress and errors will be displayed
UUT will update FPGA's flash
Runnning Diags will halt ALL activity on the requested slot.
[confirm]
Router#
PID of f_diag_run is 121, set test_pid[3]
gdb slot is 0
Launching a Field Diagnostic for slot 7
Loading c12k-fdiagsbflc-mz.new_fpga from 223.255.254.254 (via
Ethernet0):
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Calling enable_slot_and_type_on_fabric(DISABLE) for slot 7
Calling enable_slot_and_type_on_fabric(ENABLE) for slot 7
FD 3> *****************************************************
FD 3> GSR Field Diagnostics V6.9