Bridge/Router Installation and Configuration Guide
Chapter 5 Troubleshooting the Installation
Troubleshooting the Processor Subsystem
5-26
Cisco 12016, Cisco 12416, and Cisco 12816 Router Installation and Configuration Guide
OL-11495-01
DIAG
MODE
Diagnostic mode. RP
DIAG
LOAD
Downloading field diagnostics over the MBus. RP
DIAG
F_LD
Downloading field diagnostics over the fabric. RP
DIAG
STRT
Launching field diagnostics. RP
DIAG
HALT
Cancel field diagnostics. RP
DIAG
TEST
Running field diagnostics tests. RP
DIAG
PASS
1
Field diagnostics completed successfully. RP
POST
STRT
Launching power-on self-test (POST). RP
UNKN
STAT
Unknown state. RP
ADMN
DOWN
Line card is administratively down. RP
SCFG
PRES
1
Incorrect hw-module slot srp command entered. RP
SCFG
1
REDQ
Required hw-module slot srp command not entered. RP
1. This LED sequence only appears in Cisco IOS Release 12.0(24)S or later.
2. The fabric downloader loads the Cisco IOS software image onto the line card.
Table 5-4 Troubleshooting Using Other Alphanumeric Display Messages (continued)
Display Meaning Source